H7P3 Heating appliances
Part H7 Ancillary provisions and additional construction requirements · NCC 2019: TAS P2.7.3, P2.7.3
A heating appliance and its associated components within a building, including an open fire-place, chimney, or the like, must be installed—
to withstand the temperatures likely to be generated by the appliance; and
so that it does not raise the temperature of any building element to a level that would adversely affect the element’s physical or mechanical properties or function; and
so that hot products of combustion will not—
escape through the walls of the associated components; and
discharge in a position that will cause fire to spread to nearby combustible materials or allow smoke to penetrate through nearby windows, ventilation inlets, or the like in the building containing the heating appliance.