Part H7 Ancillary provisions and additional construction requirements
20 clauses · Open on NCC Online ↗
- H7O1 ObjectiveThe Objective is to— safeguard young children from drowning or injury in a swimming pool; and safeguard people from drowning or injury due to…
- H7F1 Swimming pool accessA swimming pool is to be provided with— means to restrict access to it by young children; and means to reduce the possibility of a person being…
- H7F2 Heating appliancesA heating appliance using controlled combustion located in a building is to be installed in a way which reduces the likelihood of— fire spreading…
- H7F3 Alpine areasA building in an alpine area is to be provided with additional measures in view of the increased difficulties in fighting fire and maintaining…
- H7F4 Bushfire areasA Class 1 building or a Class 10a building or deck associated with a Class 1 building constructed in a designated bushfire prone area is to provide…
- H7F5 Private bushfire sheltersA structure designed for emergency occupation during a bushfire event must provide shelter to occupants from direct and indirect actions of a…
- H7P1 Swimming pool access NSW NT QLD SAA barrier must be provided to a swimming pool and must— be continuous for the full extent of the hazard; and be of a strength and rigidity to…
- H7P2 Swimming pool reticulation systems TASA swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, a person. Applications H7P2 only…
- H7P3 Heating appliances TASA heating appliance and its associated components within a building, including an open fire-place, chimney, or the like, must be installed— to…
- H7P4 Buildings in alpine areasAn external doorway from a building in an alpine area must be installed so that opening the door is not obstructed by snow or ice. (2) A building in…
- H7P5 Buildings in bushfire prone areas NSW TASA Class 1 building, or a Class 10a building or deck associated with a Class 1 building. that is constructed in a designated bushfire prone area must…
- H7P6 Private bushfire sheltersA private bushfire shelter must be designed and constructed to provide a tenable environment for occupants during a design bushfire with an annual…
- H7V1 Combustion appliancesCompliance with H7P3(a) and (b) is verified when— components used within an appliance and its installation are constructed from— heat-resistant…
- Table H7V2 Annual Probability of Exceedance (APE) for design bushfire actionsImportance Level | Complex analysis APE for bushfire exposure | Simple analysis APE for weather conditions (design bushfire) 1 | No requirement | No…
- H7V2 Buildings in bushfire prone areasCompliance with H7P5 is verified if the ignition probability for a building exposed to a design bushfire does not exceed 10%. (2) Bushfire design…
- H7D1 Deemed-to-Satisfy provisions NSWWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements H7P1 to H7P5 are satisfied by complying with H7D2 to H7D5. (2) Where a…
- H7D2 Swimming pools NSW NT QLD SA TAS WAPerformance Requirement H7P1 is satisfied for a swimming pool with a depth of water more than 300 mm and which is associated with a Class 1…
- H7D3 Construction in alpine areasCompliance with Part 12.2 of the ABCB Housing Provisions satisfies Performance Requirement H7P4 for buildings that are located in alpine areas (2)…
- H7D4 Construction in bushfire prone areas NSW QLD SAThe requirements of (2) only apply in a designated bushfire prone area. (2) Performance Requirement H7P5 is satisfied for a Class 1 building, or a…
- H7D5 Heating appliances, fireplaces, chimneys and fluesPerformance Requirement H7P3 is satisfied for a heating appliance if it is installed in accordance with— for a domestic solid fuel burning…