NSW H1P1 Structural reliability and resistance
NSW Part H1 Structure · varies H1P1 Structural reliability and resistance
Delete clause H1P1 and insert NSW H1P1 as follows:
(1) By resisting the actions to which it may reasonably be expected to be subjected, a building or structure, during construction and use, with appropriate degrees of reliability, must—
perform adequately under all reasonably expected design actions; and
withstand extreme or frequently repeated design actions; and
be designed to sustain local damage, with the structural system as a remaining stable and not being damaged to an extent disproportionate to the original local damage; and
avoid causing damage to other properties.
(2) The actions to be considered to satisfy (1) include but are not limited to—
permanent actions (dead loads); and
imposed actions (live loads arising from occupancy and use); and
wind action; and
earthquake action; and
snow action; and
liquid pressure action; and
ground water action; and
rainwater action (including ponding action); and
earth pressure action; and
differential movement; and
time dependent effects (including creep and shrinkage); and
thermal effects; and
ground movement caused by—
swelling, shrinkage or freezing of the subsoil; and
landslip or subsidence; and
siteworks associated with the building or structure; and
construction activity actions; and
termite actions.
(3) The structural resistance of materials and forms of construction must be determined using five percentile characteristic material properties with appropriate allowance for—
known construction activities; and
type of material; and
characteristics of the site; and
the degree of accuracy inherent in the methods used to assess the structural behaviour; and
action effects arising from the differential settlement of foundations, and from restrained dimensional changes due to temperature, moisture, shrinkage, creep and similar effects.
(4) Glass installations that are at risk of being subjected to human impact must have glazing that—
if broken on impact, will break in a way that is not likely to cause injury to people; and
resists a reasonably foreseeable human impact without breaking; and
is protected or marked in a way that will reduce the likelihood of human impact.