NCC 2025 Volume Two
New South Wales variations
23 NSW variations to NCC 2025 Volume Two: clauses replaced, added or deleted in New South Wales. Search with NSW variations.
- NSW A2G2 Performance SolutionDelete clause A2G2 and insert NSW A2G2 as follows: (1) A Performance Solution is achieved by demonstrating— compliance with all relevant Performance…
- NSW A5G3 Evidence of suitability ─ Volumes One and Two (BCA)Delete clause A5G3 and insert NSW A5G3 as follows: (1) Subject to A5G5, NSW A5G6, A5G7 and A5G9, evidence to support that the use of a material,…
- NSW A5G6 Fire hazard properties and combustibilityDelete clause A5G6 and insert NSW A5G6 as follows: (1) Subject to (3), where a Deemed-to-Satisfy Provision requires a building material, component,…
- NSW A6G7 Class 6 buildingsDelete clause A6G7 and insert NSW A6G7 as follows: A Class 6 building is a shop or other building for sale of goods by retail or the supply of…
- NSW H1D1 Deemed-to-Satisfy ProvisionsDelete subclause H1D1(1) and insert NSW H1D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW H1P1…
- NSW H1D4 Footings and slabsDelete subclause H1D4(1) and insert NSW H1D4(1) as follows: (1) Performance Requirement H1P1 is satisfied for footings and slabs if they are…
- NSW H1D8 GlazingDelete subclause H1D8(3) and insert NSW H1D8(3) as follows: (3) Performance Requirement NSW H1P1(4) is satisfied for glazed assemblies at risk of…
- NSW H1P1 Structural reliability and resistanceDelete clause H1P1 and insert NSW H1P1 as follows: (1) By resisting the actions to which it may reasonably be expected to be subjected, a building…
- NSW H1V1 Structural reliabilityDelete clause H1V1 and insert NSW H1V1 as follows: (1) This Verification Method is only applicable to components with a resistance coefficient of…
- NSW H2D3 Footings and slabsDelete clause H2D3 and insert NSW H2D3 as follows: Performance Requirement NSW H2P3 is satisfied for footings and slabs if they are installed in…
- NSW H2D4 MasonryDelete subclause H2D4(2) and insert NSW H2D4(2) as follows: (2) Performance Requirements H2P2 and NSW H2P3 are satisfied for weatherproofing of…
- NSW H2D5 Subfloor ventilationDelete clause H2D5 and insert NSW H2D5 as follows: Performance Requirement NSW H2P3 is satisfied for subfloor ventilation if it is in accordance…
- NSW H2P3 Rising dampDelete clause H2P3 and insert NSW H2P3 as follows: (1) Moisture from the ground must be prevented from causing— unhealthy or dangerous conditions,…
- NSW H3D2 Fire hazard properties and non-combustible building elementsDelete clause H3D2 and insert NSW H3D2 as follows: (1) The following materials, though combustible or containing combustible fibres, may be used…
- NSW H3D5 Fire separation of garage top dwellingsDelete clause H3D5 and insert NSW H3D5 as follows: Compliance with NSW Part 9.4 of the ABCB Housing Provisions satisfies Performance Requirement…
- NSW H4D9 Condensation managementDelete clause H4D9 and insert NSW H4D9 as follows: Compliance with NSW Part 10.8 of the ABCB Housing Provisions satisfies Performance Requirement…
- NSW H7D1 Deemed-to-Satisfy provisionsDelete subclause H7D1(1) and insert NSW H7D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW H7P1 to…
- NSW H7D2 Swimming poolsDelete clause H7D2 and insert NSW H7D2 as follows: (1) Performance Requirement NSW H7P1 is satisfied for a swimming pool with a depth of water more…
- NSW H7D4 Construction in bushfire prone areasDelete clause H7D4 and insert NSW H7D4 as follows: (1) The requirements of (2) only apply in a designated bushfire prone area. (2) Performance…
- NSW H7P1 Swimming pool accessDelete clause H7P1 and insert NSW H7P1 as follows: A barrier must be provided to a swimming pool and must— be continuous for the full extent of the…
- NSW H7P5 Buildings in bushfire prone areasDelete clause H7P5 and insert NSW H7P5 as follows: A Class 1 building, or a Class 10a building or deck associated with a Class 1 building. that is…
- NSW Part H6 Energy efficiencyIntroduction to this Part This Part been deliberately left blank. Part H6 of NCC 2025 Volume Two does not apply in NSW and NSW Part H6 of NCC 2022…
- NSW Part H8 Livable housing designThis Part has deliberately been left blank. Part H8 does not apply in NSW, as livable housing design requirements do not apply to Class 1a buildings…