New South Wales variation · NCC 2025 Volume Two

NSW H1V1 Structural reliability

NSW Part H1 Structure · varies H1V1 Structural reliability of components

Open on NCC Online ↗

Delete clause H1V1 and insert NSW H1V1 as follows:

(1) This Verification Method is only applicable to components with a resistance coefficient of variation of at least 10% and not more than 40%.

(2) For components with a calculated resistance coefficient of variation value less than 10%, then a minimum value of 10% should be used.

(3) Compliance with NSW H1P1(1), (2) and (3) is verified for the design of a structural component for strength when—

the capacity reduction factor [formula] satisfies [formula] , where [formula] are capacity reduction factors for all relevant actions and must contain at least permanent (G), imposed (Q) and wind (W) actions; and

the capacity reduction factors [formula] are calculated for target reliability indices for permanent action [formula] , for imposed action [formula] , for wind action [formula] in accordance with the equation: [formula] , where—

[formula] ; and

[formula] , where—

[formula] = ratio of mean resistance to nominal; and

[formula] = ratio of mean action to nominal; and

[formula] = correction factor for action; and

[formula] = correction factor for resistance; and

[formula] = coefficient of variation of the appropriate action as given in NSW Table H1V1a; and

[formula] = coefficient of variation of the resistance; and

[formula] = appropriate load factor as given in AS/NZS 1170.0; and

[formula] = capacity factor for the appropriate action; and

the annual target reliability indices [formula] are established as follows:

For situations where it is appropriate to compare with an equivalent Deemed-to-Satisfy product, a resistance model must be established for the equivalent Deemed-to-Satisfy product and must be calculated for the equivalent Deemed-to-Satisfy product in accordance with the equation given at (b).

The target reliability indices βTG,βTQ,βTW,... thus established, must be not less than those given in NSW Table H1V1b minus 0.5.

For situations where it is not appropriate to compare with an equivalent Deemed-to-Satisfy product, the target reliability index β must be as given in NSW Table H1V1b.

(4) The resistance model for the component must be established by taking into account variability due to material properties, fabrication and construction processes and structural modelling.

Insert NSW table (H1V1a) H1V1 as follows:

NSW Table H1V1a: Annual action models

Design action

Ratio of mean action to nominal

Coefficient of variation of the action

Permanent action [formula] |

[formula] = 1.00

[formula] = 0.10

Imposed action [formula] |

[formula] = 0.50

[formula] = 0.43

Wind action [formula] (Non-cyclonic)

[formula] = 0.16

[formula] = 0.49

Wind action [formula] (Cyclonic)

[formula] = 0.16

[formula] = 0.71

Snow action [formula] |

[formula] = 0.29

[formula] = 0.57

Earthquake action [formula] |

[formula] = 0.05

[formula] = 1.98

Insert NSW table (H1V1b) H1V1 as follows:

NSW Table H1V1b: Annual target reliability indices (β)

Type of action

Target reliability index β

Permanent action

4.3

Imposed action

4.0

Wind, snow and earthquake action

3.7

Table Notes

Table H1V1b is applicable for components that exhibit brittle failure similar to concrete as specified in AS 3600.

For components with creep characteristics similar to timber as specified in AS 1720.1, the target reliability index for permanent action shall be increased to 5.0.

The above target reliability indices are based on materials or systems that exhibit creep or brittle failure characteristics similar to timber and concrete.

Table H1V1b may also be applicable to materials or systems that exhibit creep or brittle failure differently to steel, timber or concrete provided that the creep and/or brittle nature of the material or system are properly accounted for in the design model.

The above target reliability indices are also applicable for materials or systems that exhibit ductile failure characteristics.

New in NCC 2025. No NSW H1V1 in NCC 2022 Volume Two; it may have moved or been renumbered.

The national clause