South Australia variation · NCC 2025 Volume Two

SA H2D4 Masonry

SA Part H2 Damp and weatherproofing · varies H2D4 Masonry

Open on NCC Online ↗

Delete subclause H2D4(2) and insert SA H2D4(2) as follows:

(2) Performance Requirements H2P2 and SA H2P3 are satisfied for weatherproofing of masonry if it is carried out in accordance with the appropriate provisions of—

AS 3700 - Masonry structures; or

AS 4773 - Masonry for small buildings, Parts 1 and 2.

Insert SA subclause H2D4(3) in clause H2D4 as follows:

(3) For the purposes of SA H2D4(2), metals and bitumen-coated metals referred to in clauses 7.2. and 7.3 of AS/NZS 2904 are not acceptable materials for use as damp-proof courses in South Australia.

Insert SA subclause H2D4(4) in clause H2D4 as follows:

(4) In low rainfall intensity areas where the site classification is A, S, M, M-D, H, H1, H2, H-D, H1-D or H2-D in accordance with AS 2870, the height of the damp-proof course may be —

15 mm above finished paved, concreted or landscaped areas; or

0 mm if the damp-proof course is protected from the direct effects of the weather by a carport, verandah or the like.

Same wording in NCC 2022 Volume Two. See NCC 2022 Volume Two SA H2D4.

The national clause

Other states and territories