NCC 2025 Volume Two
South Australia variations
24 SA variations to NCC 2025 Volume Two: clauses replaced, added or deleted in South Australia. Search with SA variations.
- SA A6G7 Class 6 buildingsDelete clause A6G7 and insert SA A6G7 as follows: A Class 6 building is a shop or other building for the sale of goods by retail or the supply of…
- SA H1D10 Flood hazard areasThis clause has deliberately been left blank.
- SA H1P2 Buildings in flood areasThis clause has deliberately been left blank.
- SA H2D4 MasonryDelete subclause H2D4(2) and insert SA H2D4(2) as follows: (2) Performance Requirements H2P2 and SA H2P3 are satisfied for weatherproofing of…
- SA H2P3 Rising dampDelete clause H2P3 and insert SA H2P3 as follows: (1) Moisture from the ground must be prevented from causing— undue dampness or deterioration of…
- SA H3P1 Spread of fireDelete subclause H3P1(1) and insert SA H3P1(1) as follows: (1) A Class 1 building must be protected from the spread of fire such that the…
- SA H4P1 Wet areasInsert SA subclause H4P1(2) in clause H4P1 as follows: (2) Floors in bathrooms, or rooms containing a shower or sanitary fixture, must be installed…
- SA H5D1 Deemed-to-Satisfy ProvisionsDelete subclause H5D1(1) and insert SA H5D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements H5P1, H5P2…
- SA H5D4 Minimum space between buildingsInsert SA clause H5D4 in clause H5D4 as follows: (1) Compliance with (2) for acceptable separation between buildings for Class 1 and 10 buildings…
- SA H5F2 Space between buildingsInsert SA clause H5F2 in clause H5F2 as follows: The space between buildings must not allow hazardous conditions to arise due to accumulation of…
- SA H5O2 ObjectiveInsert SA clause H5O2 in clause H5O2 as follows: The Objective is to safeguard people from injury and illness resulting from the creation of…
- SA H5P3 Access for inspection and maintenanceInsert SA clause H5P3 in clause H5P3 as follows: The space between buildings must be sufficient to allow access for inspection and maintenance to…
- SA H7D2 Swimming poolsInsert SA subclause H7D2(3) in clause H7D2 as follows: (3) For the purpose of clause 6.1.1 of AS 1926.3, a skimmer box is an outlet and must have a…
- SA H7D4 Construction in bushfire prone areasInsert SA subclause H7D4(3) in clause H7D4 as follows: (3) Where a site is located in a designated bushfire prone area, the bushfire attack level…
- SA H7P1 Swimming pool accessInsert SA subclause H7P1(2) in clause H7P1 as follows: (2) A swimming pool must have prominent and visible signage that assists persons to provide…
- SA H8D2 Livable housing designDelete clause H8D2 and insert SA H8D2 as follows: (1) A Class 1a dwelling must comply with the ABCB Standard for Livable Housing Design. (2) Clause…
- SA H10D1 Deemed-to-Satisfy ProvisionsDelete clause H10D1 and insert SA H10D1 as follows: Compliance with SA H10D2 to SA H10D4 for access for people with a disability satisfies…
- SA H10D2 Application of PartDelete clause H10D2 and insert SA H10D2 as follows: This Part applies to certain Class 1 buildings where access is required under SA H10D3.
- SA H10D3 Access to buildingsDelete clause H10D3 and insert SA H10D3 as follows: In developments consisting of 20 or more dwellings, access must be provide to and within one…
- SA H10D4 Parts of buildings to be accessibleDelete clause H10D4 and insert SA H10D4 as follows: (1) Access for people with a disability must be provided from the entrance doorway to areas…
- SA H10F1 Equitable and dignified accessDelete clause H10F1 and insert SA H10F1 as follows: A building to the degree necessary is, as far as is reasonable, to provide safe, equitable and…
- SA H10O1 ObjectiveDelete clause H10O1 and insert SA H10O1 as follows: Provide, as far as is reasonable, people with safe, equitable and dignified access to a degree…
- SA H10P1 Access for people with a disabilityDelete clause H10P1 and insert SA H10P1 as follows: Buildings and immediate surrounds must have appropriate features to a degree necessary to enable…
- SA Part Part H9 * * * * *Introduction to this Part The content of SA Part H9, which exists in NCC 2022, has been removed. The Part number has been retained so as not to…