Table · NCC 2025 Volume Two

Table H1V1 Annual action models

Part H1 Structure

Open Table H1V1 on NCC Online ↗
Design actionRatio of mean action to nominalCoefficient of variation of the action
Permanent action1.050.10
Annual maximum imposed action0.350.45
Arbitrary-point-in-time imposed action0.250.78
Wind (non-cyclonic regions, Importance Level 1)0.370.47
Wind (non-cyclonic regions, Importance Level 2)0.310.47
Wind (cyclonic regions, Importance Level 1)0.190.76
Wind (cyclonic regions, Importance Level 2)0.160.76
Earthquake (Importance Level 1)0.280.90
Earthquake (Importance Level 2)0.150.90
Snow0.290.57

Table Notes

Actions not listed must be considered and derived on a case-by-case basis.

Nominal loads are based on AS/NZS 1170 series of standards.

Table for H1V1 Structural reliability of components

New in NCC 2025. No Table H1V1 in NCC 2022 Volume Two; it may have moved or been renumbered.