Table · NCC 2025 Volume Two
Table H1V1 Annual action models
| Design action | Ratio of mean action to nominal | Coefficient of variation of the action |
|---|---|---|
| Permanent action | 1.05 | 0.10 |
| Annual maximum imposed action | 0.35 | 0.45 |
| Arbitrary-point-in-time imposed action | 0.25 | 0.78 |
| Wind (non-cyclonic regions, Importance Level 1) | 0.37 | 0.47 |
| Wind (non-cyclonic regions, Importance Level 2) | 0.31 | 0.47 |
| Wind (cyclonic regions, Importance Level 1) | 0.19 | 0.76 |
| Wind (cyclonic regions, Importance Level 2) | 0.16 | 0.76 |
| Earthquake (Importance Level 1) | 0.28 | 0.90 |
| Earthquake (Importance Level 2) | 0.15 | 0.90 |
| Snow | 0.29 | 0.57 |
Table Notes
Actions not listed must be considered and derived on a case-by-case basis.
Nominal loads are based on AS/NZS 1170 series of standards.
Table for H1V1 Structural reliability of components
New in NCC 2025. No Table H1V1 in NCC 2022 Volume Two; it may have moved or been renumbered.