WA H9P2 Water loss prevention
WA Part H9 Water use
Delete clause H9P2 and insert WA H9P2 as follows:
A building, including any water holding structure, must have features that, to the degree necessary, prevent excessive loss of drinking water appropriate to—
the geographic location of the building; and
the available drinking water supply for the building; and
the function and use of the building; and
the effects of permanent features such as topography, structures and buildings.
Applications
WA H9P2 only applies to Class 1 buildings, associated Class 10a buildings and swimming pools associated with a Class 1 building.
Changed since NCC 2022. See NCC 2022 Volume Two WA H9P2, or show what changed.
Delete clause H9P2 and insert WA H9P2 as follows: A building, including any water holding structure, must have features that, to the degree necessary, prevent excessive loss of potable drinking water appropriate to — the geographic location of the building; and the available potable drinking water supply for the building; and the function and use … buildings and swimming pools associated with a Class 1 building.
Removed words are struck through; added words are highlighted. Comparison of the text only.