NCC 2025 Volume Two
Western Australia variations
13 WA variations to NCC 2025 Volume Two: clauses replaced, added or deleted in Western Australia. Search with WA variations.
- WA H3D7 Fire separation of roofed outdoor areasInsert WA clause H3D7 in clause H3D7 as follows: Compliance with WA Part 9.6 of the ABCB Housing Provisions satisfies Performance Requirements H3P1…
- WA H7D2 Swimming poolsDelete subclause H7D2(1) and insert WA H7D2(1) as follows: (1) Performance Requirement H7P1 is satisfied for a swimming pool with a depth of water…
- WA H9D1 Deemed-to-Satisfy ProvisionsDelete clause H9D1 and insert WA H9D1 as follows: (1) Performance Requirement WA H9P1 is satisfied for a building’s water use efficiency by…
- WA H9D2 Water use efficiencyDelete clause H9D2 and insert WA H9D2 as follows: (1) All tap fittings other than bath outlets and garden taps must be a minimum of 4 stars WELS…
- WA H9D3 Swimming pool covers and blanketsDelete clause H9D3 and insert WA H9D3 as follows: An outdoor private swimming pool or spa associated with a Class 1 building must be supplied with a…
- WA H9D4 Heated water use efficiencyDelete clause H9D4 and insert WA H9D4 as follows: (1) All internal heated water outlets (such as taps, showers and washing machine water supply…
- WA H9F1 Drinking water demandDelete clause H9F1 and insert WA H9F1 as follows: To reduce drinking water demand, a building is to be capable of using drinking water efficiently…
- WA H9O1 Efficient use of waterDelete clause H9O1 and insert WA H9O1 as follows: The Objective is to reduce water demand by using water efficiently and minimising water wastage.
- WA H9P1 Water use efficiencyDelete clause H9P1 and insert WA H9P1 as follows: A building must have features that, to the degree necessary, facilitate the efficient use of…
- WA H9P2 Water loss preventionDelete clause H9P2 and insert WA H9P2 as follows: A building, including any water holding structure, must have features that, to the degree…
- WA H9P3 Heated water use efficiencyDelete clause H9P3 and insert WA H9P3 as follows: A building must have features that, to the degree necessary, facilitate the efficient use of…
- WA H10D1 Eaves gutter overflowDelete clause H10D1 and insert WA H10D1 as follows: Delete clause 3.5.1 of AS/NZS 3500.3:2021 and replace with the following: 3.5.1 General Eaves…
- WA H10D2 Required size of vertical downpipesDelete clause H10D2 and insert WA H10D2 as follows: Delete Table 3.5.2 of AS/NZS 3500:2021 and replace with the following: Table H10D2 Table 3.5.2 -…