C2D15 Fixing of bonded laminated cladding panels
Part C2 Fire resistance and stability
(1) In a building required to be of Type A or B construction, externally located bonded laminated cladding panels must have all layers of cladding mechanically supported or restrained to the supporting frame.
(2) An externally located bonded laminated cladding panel need not comply with (1) if it is one of the following:
A laminated glass system.
Layered plasterboard product.
Perforated gypsum lath with a normal paper finish.
Fibrous-plaster sheet.
Fibre-reinforced cement sheeting.
A component of a garage door.
Notes
For C2D15(1), mechanical support or restraint means fixing that does not solely rely on chemical adhesive and includes concealed fixing systems such as cassette fixing, channel-type fixing and face fixing.