NCC 2025 Volume One
Part C2 Fire resistance and stability
16 clauses · Open on NCC Online ↗
- C2D1 Deemed-to-Satisfy Provisions SAWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements C1P1 to C1P9 are satisfied by complying with— C2D2 to C2D15, C3D2 to C3D15…
- Table C2D2 Type of construction requiredRise in storeys | Class of building 2, 3, 9 | Class of building 5, 6, 7, 8 4 or more | A | A 3 | A | B 2 | B | C 1 | C | C
- C2D2 Type of construction required SAThe minimum Type of fire-resisting construction of a building must be determined in accordance with Table C2D2, except as allowed for— certain Class…
- C2D3 Calculation of rise in storeysThe rise in storeys is the sum of the greatest number of storeys at any part of the external walls of the building and any storeys within the roof…
- C2D4 Buildings of multiple classificationIn a building of multiple classifications, the Type of construction required for the building is the most fire-resisting Type resulting from the…
- C2D5 Mixed types of constructionA building may be of mixed Types of construction where it is separated in accordance with C3D8 and the Type of construction is determined in…
- C2D6 Two storey Class 2, 3 or 9c buildingsA building having a rise in storeys of 2 may be of Type C construction if— it is a Class 2 or 3 building or a mixture of these classes and each…
- C2D7 Class 4 parts of buildingsFor the Type of construction required by C2D4, a Class 4 part of a building requires the same FRL for building elements and the same construction…
- C2D8 Open spectator stands and indoor sports stadiumsAn open spectator stand or indoor sports stadium may be of Type C construction and need not comply with the other provisions of this Part if it…
- C2D9 Lightweight constructionLightweight construction must comply with Specification 6 if it is used in a wall system— that is required to have an FRL; or for a lift shaft,…
- C2D10 Non-combustible building elementsIn a building required to be of Type A or B construction, the following building elements and their components must be non-combustible: External…
- C2D11 Fire hazard properties NSW VICThe fire hazard properties of the following internal linings, materials and assemblies within a Class 2 to 9 building must comply with Specification…
- C2D12 Performance of external walls in fireConcrete external walls that could collapse as complete panels (e.g. tilt-up and pre-cast concrete), in a building having a rise in storeys of not…
- C2D13 Fire-protected timber: ConcessionFire-protected timber may be used wherever an element is required to be non-combustible, provided— the building is— a separate building; or a part…
- C2D14 Ancillary elementsAn ancillary element must not be fixed, installed, attached to or supported by the concealed internal parts or external face of an external wall…
- C2D15 Fixing of bonded laminated cladding panelsIn a building required to be of Type A or B construction, externally located bonded laminated cladding panels must have all layers of cladding…