Deemed-to-Satisfy Provision · NCC 2025 Volume One

C4D2 Application of Part

Part C4 Protection of openings · NCC 2019: C3.1

Open C4D2 on NCC Online ↗

(1) The Deemed-to-Satisfy Provisions of this Part do not apply to the following:

Control joints, weep holes and the like in external walls of masonry construction and joints between panels in external walls of pre-cast concrete panel construction if, in all cases they are not larger than necessary for the purpose.

Non-combustible ventilators for subfloor or cavity ventilation, if each does not exceed 45 000 mm2 in face area and is spaced not less than 2 m from any other ventilator in the same wall.

Openings in the vertical plane formed between building elements at the construction edge or perimeter of a balcony or verandah, colonnade, terrace, or the like.

In a carpark floor other than a floor that separates a part not used as a carpark, and subject to (e), the following openings in a carpark floor:

Service penetrations.

Openings formed by a vehicle ramp.

The requirements of (d) only apply where the connected carpark levels comply as a single fire compartment for the purposes of all other requirements of the Deemed-to-Satisfy Provisions of Sections C, D and E.

(2) For the purposes of the Deemed-to-Satisfy Provisions of this Part, openings in building elements required to be fire-resisting include doorways, windows (including any associated fanlight), infill panels and fixed or openable glazed areas that do not have the required FRL.

(3) For the purposes of the Deemed-to-Satisfy Provisions of this Part, openings, other than those covered under (1)(c), between building elements such as columns, beams and the like, in the plane formed at the construction edge or perimeter of the building, are deemed to be openings in an external wall.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One C4D2.
Can't meet C4D2? A Performance Solution must meet the Performance Requirements it satisfies: C1P1, C1P2, C1P3, C1P4, C1P5, C1P6, C1P7, C1P8, C1P9. Start a Performance Solution →

Defined terms used