Deemed-to-Satisfy Provision · NCC 2025 Volume One

D2D15 Discharge from exits

Part D2 Provision for escape · NCC 2019: D1.10

Open D2D15 on NCC Online ↗
Varied in NSW. Check the variation for your state.

(1) An exit must not be blocked at the point of discharge and where necessary, suitable barriers must be provided to prevent vehicles from blocking the exit, or access to it.

(2) If a required exit leads to an open space, the path of travel to the road must have an unobstructed width throughout of not less than—

the minimum width of the required exit; or

1 m,

whichever is the greater.

(3) If an exit discharges to open space that is at a different level than the public road to which it is connected, the path of travel to the road must be by—

a ramp or other incline having a gradient not steeper than 1:8 at any part, or not steeper than 1:14 if required by the Deemed-to-Satisfy Provisions of Part D4; or

except if the exit is from a Class 9a building, a stairway complying with the Deemed-to-Satisfy Provisions of the NCC.

(4) The discharge point of alternative exits must be located as far apart as practical.

(5) In a Class 9b building which is an open spectator stand that accommodates more than 500 persons, a required stairway or required ramp must not discharge to the ground in front of the stand.

(6) In a Class 9b building containing an auditorium which accommodates more than 500 persons, not more than ⅔ of the required width of exits must be located in the main entrance foyer.

(7) The number of persons accommodated must be calculated according to D2D18.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One D2D15.
Can't meet D2D15? A Performance Solution must meet the Performance Requirements it satisfies: D1P1, D1P2, D1P3, D1P4, D1P5, D1P6, D1P8, D1P10, D1P9. Start a Performance Solution →

State and territory variations all clauses side by side →

Clauses referred to

Defined terms used