Part E4 Visibility in an emergency, exit signs and warning systems · NCC 2019: SA E4.8(c), E4.8
Every required exit sign must—
comply with—
AS/NZS 2293.1; or
for a passive photoluminescent exit sign, Specification 25; or
for a hybrid photoluminescent exit sign, SA TS 5367; and
be clearly visible at all times when the building is occupied by any person having the right of legal entry to the building.
Changed since NCC 2022. See NCC 2022 Volume One E4D8, or show what changed.
Every required exit sign must — comply with — AS/NZS 2293.1; or for a passive photoluminescent exit sign, Specification 25; or for a hybrid photoluminescent exit sign, SA TS 5367; and be clearly visible at all times when the building is occupied by any person having the right of legal entry to the building.