Deemed-to-Satisfy Provision · NCC 2025 Volume One

F6D10 Airlocks

Part F6 Light and ventilation · NCC 2019: F4.9

Open F6D10 on NCC Online ↗

If a sanitary compartment is prohibited under F6D9 from opening directly to another room—

in a sole-occupancy unit in a Class 2 or 3 building or Class 4 part of a building—

access must be by an airlock, hallway or other room; or

the sanitary compartment must be provided with mechanical exhaust ventilation; and

in a Class 5, 6, 7, 8 or 9 building (which is not an early childhood centre, primary school or open spectator stand)—

access must be by an airlock, hallway or other room with a floor area of not less than 1.1 m2 and fitted with self-closing doors at all access doorways; or

the sanitary compartment must be provided with mechanical exhaust ventilation and the doorway to the room adequately screened from view.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One F6D10.
Can't meet F6D10? A Performance Solution must meet the Performance Requirements it satisfies: F6P1, F6P2, F6P3, F6P4, F6P5. Start a Performance Solution →