Deemed-to-Satisfy Provision · NCC 2025 Volume One

G1D4 Outdoor play spaces

Part G1 Minor structures and components · NCC 2019: G1.3

Open G1D4 on NCC Online ↗

(1) Any outdoor play space in a Class 9b early childhood centre must be enclosed on all sides with a barrier which—

where the edge of the trafficable surface of the outdoor play space is at the same level or less than 2 m above the surface beneath — complies with AS 1926.1, except ‘This clause shall not apply to boundary barriers.’ in clause 2.3.1 is replaced with ‘This clause shall apply to boundary barriers.’; and

where the edge of the trafficable surface of the outdoor play space is 2 m or more above the surface beneath—

is not less than 1.8 m high, as measured from above the trafficable surface; and

is non-climbable and does not contain horizontal or other elements that could facilitate climbing; and

does not have any openings or apertures through which a 100 mm or greater sphere could pass; and

is not within 1.8 m, as measured directly from the top of the barrier, of any elements within the outdoor play space that facilitate climbing; and

is not within 900 mm of elements in a wall that facilitate climbing; and

has strength and rigidity complying with AS 1926.1.

(2) For the purposes of (1)(a), AS 1926.1 is applied as if there is a swimming pool located outside the outdoor play space, so that the barrier restricts children from exiting the premises without the knowledge of staff in the centre.

(3) The requirements of (1) do not apply to a wall, including doors and windows, which form part of the Class 9b early childhood centre, except where the wall is within a non-climbable zone for a barrier provided under (1)(a).

Changed since NCC 2022. See NCC 2022 Volume One G1D4, or show what changed.

(1) Any outdoor play space in a Class 9b early … 2 m above the surface beneath — complies with AS 1926.1; 1926.1, except ‘This clause shall not apply to boundary barriers.’ in clause 2.3.1 is replaced with ‘This clause shall apply to boundary barriers.’; and where the edge of the trafficable surface of the … within a non-climbable zone for a barrier provided under (1)(a).

Removed words are struck through; added words are highlighted. Comparison of the text only.

Can't meet G1D4? A Performance Solution must meet the Performance Requirements it satisfies: G1P1, G1P2, G1P3, G1P4, G1P5. Start a Performance Solution →

Defined terms used