New South Wales variation · NCC 2025 Volume One

NSW D2D8 Width of exits and paths of travel to exits

NSW Part D2 Provision for escape · varies D2D8 Width of exits and paths of travel to exits

Open on NCC Online ↗

Insert NSW subclause D2D8(5) in clause D2D8 as follows:

(5) In a Class 9b building used as an entertainment venue —

the aggregate width must be not less than 2 m plus 500 mm for every 50 persons or part in excess of 200; and

D2D8(1), (2) and (3) do not apply; and

where one or more paths of travel merge, the width of the combined path of travel must be not less than the sum of the required widths of those paths of travel; and

the required widths of those paths of travel connecting the exits from the building to a public road or open space must comply with (c); or

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One NSW D2D8.

The national clause