NCC 2025 Volume One
New South Wales variations
178 NSW variations to NCC 2025 Volume One: clauses replaced, added or deleted in New South Wales. Search with NSW variations.
- NSW Material or assembly location Flammability Index Spread-of-Flame Index Smoke-Developed Index Fire control rooms subject to Specification 19 and…
- NSW A2G2 Performance SolutionDelete clause A2G2 and insert NSW A2G2 as follows: (1) A Performance Solution is achieved by demonstrating— compliance with all relevant Performance…
- NSW A5G3 Evidence of suitability ─ Volumes One and Two (BCA)Delete clause A5G3 and insert NSW A5G3 as follows: (1) Subject to A5G5, NSW A5G6, A5G7 and A5G9, evidence to support that the use of a material,…
- NSW A5G6 Fire hazard properties and combustibilityDelete clause A5G6 and insert NSW A5G6 as follows: (1) Subject to (3), where a Deemed-to-Satisfy Provision requires a building material, component,…
- NSW A6G7 Class 6 buildingsDelete clause A6G7 and insert NSW A6G7 as follows: A Class 6 building is a shop or other building for sale of goods by retail or the supply of…
- NSW B1D1 Deemed-to-Satisfy ProvisionsDelete subclause B1D1(1) and insert NSW B1D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW B1P1,…
- NSW B1P1 Structural reliabilityDelete clause B1P1 and insert NSW B1P1 as follows: (1) By resisting the actions to which it may reasonably be expected to be subjected, a building…
- NSW B1P4 Structural resistanceInsert NSW clause B1P4 in clause B1P4 as follows: The structural resistance of materials and forms of construction must be determined using five…
- NSW B1V1 Structural reliabilityDelete clause B1V1 and insert NSW B1V1 as follows: (1) This Verification Method is applicable to components with a resistance coefficient of…
- NSW C1V3 Fire spread via external wallsDelete clause C1V3 and insert NSW C1V3 as follows: Compliance with C1P2 to avoid the spread of fire via the external wall of a building is verified…
- NSW C2D11 Fire hazard propertiesDelete clause C2D11 and insert NSW C2D11 as follows: (1) The fire hazard properties of the following internal linings, materials and assemblies…
- NSW C3D6 Class 9 buildingsDelete subclause C3D6(3) and insert NSW C3D6(3) as follows: (3) A Class 9c building must comply with the following: A building must be divided into…
- NSW C4D12 Bounding construction: Class 2 and 3 buildings and Class 4 partsDelete subclause C4D12(4) and insert NSW C4D12(4) as follows: (4) Except as provided for in NSW C4D12(5), protection for a doorway required under…
- NSW D2D1 Deemed-to-Satisfy ProvisionsDelete subclause D2D1(1) and insert NSW D2D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to…
- NSW D2D3 Number of exits requiredDelete subclause D2D3(4) and insert NSW D2D3(4) as follows: (4) Class 9 buildings— In addition to any horizontal exit, not less than 2 exits must be…
- NSW D2D8 Width of exits and paths of travel to exitsInsert NSW subclause D2D8(5) in clause D2D8 as follows: (5) In a Class 9b building used as an entertainment venue — the aggregate width must be not…
- NSW D2D9 Width of doorways in exits or paths of travel to exitsDelete clause D2D9 and insert NSW D2D9 as follows: In a required exit or path of travel to an exit, the unobstructed width of a doorway must be not…
- NSW D2D15 Discharge from exitsDelete subclause D2D15(6) and insert NSW D2D15(6) as follows: (6) In a Class 9b building used as an entertainment venue, at least half of the…
- NSW D3D1 Deemed-to-Satisfy ProvisionsDelete subclause D3D1(1) and insert NSW D3D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to…
- NSW D3D2 Application of PartDelete clause D3D2 and insert NSW D3D2 as follows: (1) Except for— D3D14, D3D15(a), D3D17, D3D18, D3D19, D3D20, D3D22(5), D3D22(6), D3D26 and D3D29,…
- NSW D3D14 Goings and risersDelete subclause D3D14(1) and insert NSW D3D14(1) as follows: (1) A stairway must have— not more than 18 and not less than 2 risers in each flight;…
- NSW D3D16 ThresholdsDelete clause D3D16 and insert NSW D3D16 as follows: The threshold of a doorway must not incorporate a step or ramp at any point closer to the…
- NSW D3D18 Height of barriersDelete subclause D3D18(1) and insert NSW D3D18(1) as follows: (1) The height of a barrier required by D3D17 must be not less than the following: For…
- NSW D3D24 Doorways and doorsDelete subclause D3D24(2) and insert NSW D3D24(2) as follows: (2) A doorway serving as a required exit or forming part of a required exit, or a…
- NSW D3D26 Operation of latchDelete subclause D3D26(5) and insert NSW D3D26(5) as follows: (5) The requirements of (1) and (2) do not apply in a Class 9b building (other than a…
- NSW D3D32 Doors in paths of travel to an entertainment venueInsert NSW clause D3D32 in clause D3D32 as follows: In a Class 9b building used as an entertainment venue, a doorway in a path of travel must comply…
- NSW D4D1 Deemed-to-Satisfy ProvisionsDelete subclause D4D1(1) and insert NSW D4D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to…
- NSW E2D1 Deemed-to-Satisfy ProvisionsDelete subclause E2D1(1) and insert NSW E2D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements E2P1 and…
- NSW E2D2 Application of partDelete subclause E2D2(2) and insert NSW E2D2(2) as follows: (2) In addition to the Deemed-to-Satisfy Provisions of E2D3 to E2D13, the following…
- NSW E2D10 Buildings not more than 25 m in effective height: large isolated buildings subject to C3D4Delete clause E2D10 and insert NSW E2D10 as follows: (1) In a Class 5, 6, 7, 8 or 9 building of not more than 25 m in effective height, and which…
- NSW E2D16 Class 9b – assembly buildings: allDelete clause E2D16 and insert NSW E2D16 as follows: The following provisions apply to all Class 9b assembly buildings: A building or part of a…
- NSW E2D17 Class 9b – assembly buildings: night clubs, discotheques and the likeDelete clause E2D17 and insert NSW E2D17 as follows: A building or part of a building being a night club, discotheque or the like, must be provided…
- NSW E2D18 Class 9b – assembly buildings: exhibition halls, museums and art galleriesDelete clause E2D18 and insert NSW E2D18 as follows: A building or part of a building used as an exhibition hall, museum, art gallery or the like,…
- NSW E2D19 Class 9b – assembly buildings: other assembly buildings (not listed in NSW E2D16 to E2D18)Delete clause E2D19 and insert NSW E2D19 as follows: (1) Unless otherwise described in (2), in a building or part of a building used as an assembly…
- NSW E2D20 Class 9b assembly buildings: other assembly buildings (not listed in E2D16 to E2D19)This clause has deliberately been left blank. E2D20 does not apply in NSW. This clause is deleted from the BCA in NSW, as requirements for Class 9b…
- NSW E2D21 Provision for special hazardsDelete clause E2D21 and insert NSW E2D21 as follows: Additional smoke hazard management measures may be necessary due to the— special…
- NSW E4D6 Direction signsDelete clause E4D6 and insert NSW E4D6 as follows: If an exit is not readily apparent to persons occupying or visiting the building, then exit signs…
- NSW F4D10 Microbial (legionella) controlThis clause has deliberately been left blank. F4D10 does not apply in NSW as the installation of hot water, warm water and cooling water systems…
- NSW F4P6 Microbial control for water systemsThis clause has deliberately been left blank. F4P6 does not apply in NSW as the installation of hot water, warm water and cooling water systems (and…
- NSW F6D6 Ventilation of roomsDelete clause F6D6 and insert NSW F6D6 as follows: A habitable room, office, shop, factory, workroom, sanitary compartment, bathroom, shower room,…
- NSW G1D1 Deemed-to-Satisfy ProvisionsDelete subclause G1D1(1) and insert NSW G1D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G1P1 to NSW…
- NSW G1D2 Swimming poolsDelete clause G1D2 and insert NSW G1D2 as follows: (1) NSW G1D2(2) applies to the technical construction requirements for barriers to restrict…
- NSW G1D6 Cleaning windowsInsert NSW clause G1D6 in clause G1D6 as follows: A building that includes windows located 3 or more storeys above ground level satisfies…
- NSW G1F5 Cleaning of windowsInsert NSW clause G1F5 in clause G1F5 as follows: A building is to be provided with a means to allow for the safe cleaning of windows. Applications…
- NSW G1O1 ObjectiveDelete clause G1O1 and insert NSW G1O1 as follows: The Objective of this Part is to— safeguard people from illness caused by the discharge of…
- NSW G1P2 Swimming pool access and water recirculation systemsDelete clause G1P2 and insert NSW G1P2 as follows: (1) A barrier must be provided to a swimming pool and must— be continuous for the full extent of…
- NSW G1P6 Cleaning of windowsInsert NSW clause G1P6 in clause G1P6 as follows: A building must provide for a safe manner for the cleaning of windows. Applications NSW G1P6 only…
- NSW G5D1 Deemed-to-Satisfy ProvisionsDelete subclause G5D1(1) and insert NSW G5D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW G5P1…
- NSW G5D2 Application of PartDelete clause G5D2 and insert NSW G5D2 as follows: The Deemed-to-Satisfy Provisions of this Part apply in a designated bushfire prone area to— a…
- NSW G5D3 ProtectionDelete clause G5D3 and insert NSW G5D3 as follows: In a designated bushfire prone area, a Class 2 building, a Class 3 building, a Class 4 part of a…
- NSW G5D4 Protection – Class 9 buildings used as a special fire protection purposeDelete clause G5D4 and insert NSW G5D4 as follows: In a designated bushfire prone area, a Class 9 building that is a special fire protection purpose…
- NSW G5F1 Construction in bushfire prone areasDelete clause G5F1 and insert NSW G5F1 as follows: A building constructed in a designated bushfire prone area — is to provide a resistance to…
- NSW G5O1 ObjectiveDelete clause G5O1 and insert NSW G5O1 as follows: The Objective of this Part is to— safeguard occupants from injury from the effects of a bushfire;…
- NSW G5P1 Bushfire resistanceDelete clause G5P1 and insert NSW G5P1 as follows: Except as amended by Planning for Bush Fire Protection, a building that is constructed in a…
- NSW G5P2 Additional bushfire requirements for Class 9 buildings that are a special fire protection purposeDelete clause G5P2 and insert NSW G5P2 as follows: Except as amended by Planning for Bush Fire Protection, a building that is constructed in a…
- NSW G5V1 Buildings in bushfire prone areasDelete clause G5V1 and insert NSW G5V1 as follows: (1) Compliance with Performance Requirement G5P1 is verified if the ignition probability for a…
- NSW I1D1 Application of PartDelete clause I1D1 and insert NSW I1D1 as follows: (1) For a Class 9b building or part of a building that is not an entertainment venue — the…
- NSW I4D1 Application of PartDelete clause I4D1 and insert NSW I4D1 as follows: This Part applies to every entertainment venue as described in the Environmental Planning and…
- NSW I4D2 Fire separationDelete clause I4D2 and insert NSW I4D2 as follows: If an entertainment venue forms part only of a building, then— the whole of the entertainment…
- NSW I4D3 Foyer spaceDelete clause I4D3 and insert NSW I4D3 as follows: Where an entertainment venue is used principally for the purpose of— exhibiting films; or…
- NSW I4D4 Sprinkler systems for common foyersDelete clause I4D4 and insert NSW I4D4 as follows: In an entertainment venue, where multiple auditoriums have a foyer in common, the following…
- NSW I4D5 Conventional stages: applicationDelete clause I4D5 and insert NSW I4D5 as follows: NSW I4D6 to NSW I4D9 apply to a conventional stage, that is, a stage which is separated from the…
- NSW I4D6 Conventional stages: extent of stage areaDelete clause I4D6 and insert NSW I4D6 as follows: If a room or area is not separated from the remainder of a conventional stage by construction…
- NSW I4D7 Conventional stages: small stagesDelete clause I4D7 and insert NSW I4D7 as follows: A stage which is more than 50 m2 but not more than 150 m2 in area must have 2 or more means of…
- NSW I4D8 Conventional stages: large stagesDelete clause I4D8 and insert NSW I4D8 as follows: A stage which is more than 150 m2 in area— must have installed directly above the stage a…
- NSW I4D9 Conventional stages: fire separation of stagesDelete clause I4D9 and insert NSW I4D9 as follows: A stage which is more than 50 m2 in area, and all areas below such a stage, must (with the…
- NSW I4D10 Non-conventional stages: applicationDelete clause I4D10 and insert NSW I4D10 as follows: NSW I4D11 and NSW I4D12 apply to a stage that is not a conventional stage within the meaning of…
- NSW I4D11 Non-conventional stages: small stagesDelete clause I4D11 and insert NSW I4D11 as follows: A stage which is more than 50 m2 but not more than 150 m2 in area must have at least 2 means of…
- NSW I4D12 Non-conventional stages: large stagesDelete clause I4D12 and insert NSW I4D12 as follows: A stage which is more than 150 m2 in area must have at least 2 means of egress from the…
- NSW I4D13 Flying sceneryDelete clause I4D13 and insert NSW I4D13 as follows: (1) Where there is a grid or other means of flying scenery over a conventional stage or…
- NSW I4D14 Load noticeDelete clause I4D14 and insert NSW I4D14 as follows: (1) A notice indicating the actual distributed and concentrated load for which the stage floor…
- NSW I4D15 Safety curtainsDelete clause I4D15 and insert NSW I4D15 as follows: A safety curtain required by NSW I4D8 must— be made of non-combustible material; and be so…
- NSW I4D16 Safety curtains — additional requirementsDelete clause I4D16 and insert NSW I4D16 as follows: A rigid safety curtain required by NSW I4D13 must comply with the requirements of NSW I4D15 and…
- NSW I4D17 Seating in rows: applicationDelete clause I4D17 and insert NSW I4D17 as follows: NSW I4D18 to NSW I4D25 do not apply to continental seating or seating at tables.
- NSW I4D18 Seating in rows: number of seatsDelete clause I4D18 and insert NSW I4D18 as follows: Subject to NSW I4D22, where seating is arranged in rows, the maximum number of seats in each…
- NSW I4D19 Seating in rows: chairs used for seatingDelete clause I4D19 and insert NSW I4D19 as follows: Chairs used for seating must— where they have arms, be at least 500 mm from centre to centre;…
- NSW I4D20 Seating in rows: chairs in auditoriums — level floorsDelete clause I4D20 and insert NSW I4D20 as follows: Chairs in an auditorium that has a level floor must be— securely fastened to the floor; or…
- NSW I4D21 Seating in rows: chairs in auditoriums — sloping floorsDelete clause I4D21 and insert NSW I4D21 as follows: Chairs in an auditorium having a sloping floor, or having stepped or inclined platforms, must…
- NSW I4D22 Seating in rows: radiating aisles in seating areasDelete clause I4D22 and insert NSW I4D22 as follows: Where seating is securely fastened to the floor and arranged in rows of concentric circles,…
- NSW I4D23 Seating in rows: aisles and cross-oversDelete clause I4D23 and insert NSW I4D23 as follows: Where aisles and cross-overs are provided— each aisle must have a width of at least 1000 mm and…
- NSW I4D24 Seating in rows: platforms and stepsDelete clause I4D24 and insert NSW I4D24 as follows: Where an aisle contains platforms or steps— the platforms and steps must extend for the full…
- NSW I4D25 Seating in rows: stepped platformsDelete clause I4D25 and insert NSW I4D25 as follows: Where stepped platforms without chairs or stepped platforms with bench seats, are used for…
- NSW I4D26 Continental seating: applicationDelete clause I4D26 and insert NSW I4D26 as follows: NSW I4D27 to NSW I4D35 apply to continental seating.
- NSW I4D27 Continental seating: seating to be fastenedDelete clause I4D27 and insert NSW I4D27 as follows: Seating must be securely fastened to the floor.
- NSW I4D28 Continental seating: maximum seats per rowDelete clause I4D28 and insert NSW I4D28 as follows: The number of seats in a row must not exceed 120.
- NSW I4D29 Continental seating: depth of seatingDelete clause I4D29 and insert NSW I4D29 as follows: The depth of each row of seating (that is, the distance between the back of the row in front…
- NSW I4D30 Continental seating: clearance between rowsDelete clause I4D30 and insert NSW I4D30 as follows: The minimum lateral clearance between each row of seating must, in respect of a row containing…
- NSW I4D31 Continental seating: chairs used for seatingDelete clause I4D31 and insert NSW I4D31 as follows: Chairs used for seating must comply with NSW I4D19(a) and (b).
- NSW I4D32 Continental seating: egress doorwaysDelete clause I4D32 and insert NSW I4D32 as follows: Egress doorways through the walls of the auditorium — must have an aggregate width of at least…
- NSW I4D33 Continental seating: clear areasDelete clause I4D33 and insert NSW I4D33 as follows: A clear area— must be provided from each end of each row to an egress doorway in the wall of…
- NSW I4D34 Continental seating: minimum clear spaceDelete clause I4D34 and insert NSW I4D34 as follows: At the entrance from a row to a clear area, there must be a clear level floor space having a…
- NSW I4D35 Continental seating: doorsDelete clause I4D35 and insert NSW I4D35 as follows: A door fitted to the egress doorway in the wall of an auditorium must comply with NSW D3D16 and…
- NSW I4D36 Provision of guardrails: locationDelete clause I4D36 and insert NSW I4D36 as follows: Guardrails must be provided— along the fascia of each balcony or box; and if there is a stepped…
- NSW I4D37 Provision of guardrails: fixed back seatsDelete clause I4D37 and insert NSW I4D37 as follows: If seats with fixed backs are provided, guardrails that extend for the full width of the…
- NSW I4D38 Provision of guardrails: steps between platformsDelete clause I4D38 and insert NSW I4D38 as follows: If— there is more than one intervening step in an aisle between levels of platforms, a…
- NSW I4D39 Guardrails for seating areas: applicationDelete clause I4D39 and insert NSW I4D39 as follows: NSW I4D40 to NSW I4D42 apply to seating areas.
- NSW I4D40 Guardrails for seating areas: continental seatingDelete clause I4D40 and insert NSW I4D40 as follows: Where a guardrail is provided in front of a row of chairs— the distance between the back of…
- NSW I4D41 Guardrails for seating areas: balconies and boxesDelete clause I4D41 and insert NSW I4D41 as follows: A guardrail provided along the fascia of a balcony or box— if it is located at the foot of a…
- NSW I4D42 Guardrails for seating areas: cross-oversDelete clause I4D42 and insert NSW I4D42 as follows: A guardrail provided along the front edge of a cross-over on a stepped floor— must be at least…
- NSW I4D43 Dressing roomsDelete clause I4D43 and insert NSW I4D43 as follows: A dressing room or two or more adjoining dressing rooms, having a total floor area of more than…
- NSW I4D44 StoreroomsDelete clause I4D44 and insert NSW I4D44 as follows: A storeroom must be separated from other parts of the building by construction having an FRL of…
- NSW I4D45 Projection suites: ApplicationDelete clause I4D45 and insert NSW I4D45 as follows: (1) NSW I4D45 to NSW I4D48 apply to projection suites. (2) A projection suite must be provided…
- NSW I4D46 Projection suites: rooms to be providedDelete clause I4D46 and insert NSW I4D46 as follows: A projection suite in accordance with the staffing requirements of Section 72 of the…
- NSW I4D47 Projection suites: fire separationDelete clause I4D47 and insert NSW I4D47 as follows: A projection suite must be separated from all other internal parts of the building in which it…
- NSW I4D48 Projection suites: concession for protection of some openingsDelete clause I4D48 and insert NSW I4D48 as follows: If a projection or observation port is not more than 0.1 m2 in area— a metal shutter not less…
- NSW I4D49 Basement storeysDelete clause I4D49 and insert NSW I4D49 as follows: Where an entertainment venue includes not more than 2 basement storeys — all required exits…
- NSW I4D50 Basement storeys: more than twoDelete clause I4D50 and insert NSW I4D50 as follows: If the entertainment venue includes more than 2 basement storeys — the construction must be of…
- NSW I4D51 Electric mains installation: main switchboardDelete clause I4D51 and insert NSW I4D51 as follows: The switchboard containing the main isolation switch must— be located in a position that is…
- NSW I4D52 Electric mains installation: circuit protectionDelete clause I4D52 and insert NSW I4D52 as follows: Protection of the final sub-circuit originating at a switchboard or distribution board must be…
- NSW I4D53 Electric mains installation: separate sub-mainsDelete clause I4D53 and insert NSW I4D53 as follows: Where an entertainment venue has its mains supply in common with that of another building or…
- NSW I4D54 Lighting: lighting switchesDelete clause I4D54 and insert NSW I4D54 as follows: (1) Any switch controlling the lighting system must not be accessible. (2) Where, during normal…
- NSW I4D55 Lighting: lighting levelsDelete clause I4D55 and insert NSW I4D55 as follows: Where the lamps utilised in the general lighting are of a type that will not relight…
- NSW I4D56 Lighting: provision of aisle lightingDelete clause I4D56 and insert NSW I4D56 as follows: Where general lighting is to be either dimmed or extinguished when the public is in attendance…
- NSW I4D57 Lighting: aisle lighting power supplyDelete clause I4D57 and insert NSW I4D57 as follows: Where an aisle light is installed in a seat frame, it must be supplied at a voltage of not more…
- NSW I4D58 Lighting: aisle lighting alternative lighting supplyDelete clause I4D58 and insert NSW I4D58 as follows: Aisle lighting must be provided with an alternative electricity supply that— is capable of…
- NSW I4D59 Automatic smoke-and-heat vents for stagesDelete clause I4D59 and insert NSW I4D59 as follows: An automatic smoke-and-heat vent system required by NSW E2D16(c) for stages and backstages…
- NSW I4D60 Solid fuel burning stoves and open fire placesDelete clause I4D60 and insert NSW I4D60 as follows: Solid fuel burning stoves and open fire places must not be installed in premises designed for…
- NSW I4D61 Fuel gas cylinders: generalDelete clause I4D61 and insert NSW I4D61 as follows: Fuel gas cylinders must— be housed in an enclosure that is located outside the building; and…
- NSW I4D62 Fuel gas cylinders: enclosuresDelete clause I4D62 and insert NSW I4D62 as follows: An enclosure referred to in NSW I4D61 — must be located not less than 3 m from any window,…
- NSW I5D1 Application of PartDelete clause I5D1 and insert NSW I5D1 as follows: This Part applies to temporary structures used as entertainment venues.
- NSW I5D2 Exits — exclusionsDelete clause I5D2 and insert NSW I5D2 as follows: In this Part, a reference to an entrance or exit does not include a reference to an entrance or…
- NSW I5D3 Location of exitsDelete clause I5D3 and insert NSW I5D3 as follows: Exits must be so provided and arranged as to afford a ready means of egress from all parts of a…
- NSW I5D4 Exits to be providedDelete clause I5D4 and insert NSW I5D4 as follows: Without limiting the generality of NSW I5D3 — the number of exits to be provided for a temporary…
- NSW I5D5 Vertical clearance for exitsDelete clause I5D5 and insert NSW I5D5 as follows: Every part of an entrance or exit must provide a minimum unobstructed height of 2000 mm and,…
- NSW I5D6 Curtains across exitsDelete clause I5D6 and insert NSW I5D6 as follows: A flap or curtain used to cover an exit must be so designed that, when it is secured, it will not…
- NSW I5D7 Curtains and blindsDelete clause I5D7 and insert NSW I5D7 as follows: Curtains and blinds for use in a temporary structure must comply with NSW Table S7C7.
- NSW I5D8 FabricsDelete clause I5D8 and insert NSW I5D8 as follows: Fabric that is used in the construction of a temporary structure must have— a Flammability Index…
- NSW I5D9 GuardrailsDelete clause I5D9 and insert NSW I5D9 as follows: (1) A rigid guardrail must be provided at each end of a stepped or inclined platform, at least…
- NSW I5D10 SeatingDelete clause I5D10 and insert NSW I5D10 as follows: Seating must be provided in accordance with NSW I4D18, NSW I4D19, NSW I4D20(b), NSW I4D22(a)…
- NSW I5D11 Sanitary accommodationDelete clause I5D11 and insert NSW I5D11 as follows: Suitable sanitary accommodation must be provided at a location convenient to the temporary…
- NSW I5D12 Projection suitesDelete clause I5D12 and insert NSW I5D12 as follows: Any projection suite must comply with NSW I4D47 and NSW I4D48.
- NSW I5D13 Fireplaces and heatingDelete clause I5D13 and insert NSW I5D13 as follows: No fireplace or other form of heating equipment may be installed in a temporary structure,…
- NSW I5D14 Electrical servicesDelete clause I5D14 and insert NSW I5D14 as follows: Electrical services connected to the local supply authority’s mains, to a generating plant or…
- NSW I5D15 Artificial lighting: generalDelete clause I5D15 and insert NSW I5D15 as follows: Artificial lighting must be provided, and must comply with NSW I4D54 and NSW I4D55.
- NSW I5D16 Emergency lightingDelete clause I5D16 and insert NSW I5D16 as follows: Emergency lighting must be provided to the areas provided with artificial lighting under NSW…
- NSW I5D17 Emergency lighting power supplyDelete clause I5D17 and insert NSW I5D17 as follows: Where emergency lighting is provided, the capacity of the battery and charging system must be…
- NSW I5D18 Exit signsDelete clause I5D18 and insert NSW I5D18 as follows: Exit signs must be provided above all exits and in such other locations as may be required by…
- NSW I5D19 Fire-fighting servicesDelete clause I5D19 and insert NSW I5D19 as follows: (1) Fire-fighting services and appliances must be so provided as to afford adequate protection…
- NSW I6D1 Application of PartDelete clause I6D1 and insert NSW I6D1 as follows: This Part applies to drive-in theatres.
- NSW I6D2 Speaker standardsDelete clause I6D2 and insert NSW I6D2 as follows: Speaker standards must— be placed at a minimum of 5.5 m centres in a line along each parking…
- NSW I6D3 Lines of speaker standardsDelete clause I6D3 and insert NSW I6D3 as follows: Lines of speaker standards along parking ramps must be placed at a distance of not less than 12.2…
- NSW I6D4 Electrical servicesDelete clause I6D4 and insert NSW I6D4 as follows: The following electrical services must be installed underground— the supply authority’s…
- NSW I6D5 Vehicular entrancesDelete clause I6D5 and insert NSW I6D5 as follows: Each public vehicular entrance to or exit from the drive-in theatre must be capable of being…
- NSW I6D6 LightingDelete clause I6D6 and insert NSW I6D6 as follows: (1) Driveways — Entrance and exit driveways, and the perimeter of the holding area, must be…
- NSW J1F1 Energy efficiencyInsert NSW clause J1F1 in clause J1F1 as follows: A building must— reduce the energy consumption and energy peak demand of key energy using…
- NSW J1O1 ObjectiveInsert NSW clause J1O1 in clause J1O1 as follows: The Objective of this Section is to— reduce energy consumption and energy peak demand; and reduce…
- NSW J1P1 Operational energy use and greenhouse gas emissionsInsert NSW clause J1P1 in clause J1P1 as follows: A building including its services, must have features that— facilitate the efficient use of energy…
- NSW J1P2 Thermal performance of a Class 4 part of buildingInsert NSW clause J1P2 in clause J1P2 as follows: This clause has deliberately been left blank. J1P2 does not apply in NSW as thermal performance of…
- NSW J1P3 Energy usage of a Class 4 part of a buildingInsert NSW clause J1P3 in clause J1P3 as follows: This clause has deliberately been left blank. J1P3 does not apply in NSW as the thermal…
- NSW J1P4 Renewable energy, energy storage and electric vehicle chargingInsert NSW clause J1P4 in clause J1P4 as follows: A building must have features that facilitate the future installation of on-site renewable energy…
- NSW J1V1 NABERS EnergyInsert NSW clause J1V1 in clause J1V1 as follows: (1) For a Class 5 building, compliance with NSW J1P1 is verified when— a minimum 6-star NABERS…
- NSW J1V2 Green starInsert NSW clause J1V2 in clause J1V2 as follows: (1) For a Class 3, 5, 6, 7, 8 or 9 building, compliance with NSW J1P1 is verified when— the…
- NSW J1V3 Verification using a reference buildingInsert NSW clause J1V3 in clause J1V3 as follows: (1) For a Class 3, 5, 6, 7, 8 or 9 building, compliance with NSW J1P1 is verified when— it is…
- NSW J1V4 Verification of building envelope sealingInsert NSW clause J1V4 in clause J1V4 as follows: Compliance with NSW J1P1(a) is verified for building envelope sealing when the envelope is sealed…
- NSW J2D1 Deemed-to-Satisfy ProvisionsDelete subclause J2D1(1) and insert NSW J2D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1…
- NSW J2D2 Application of Section JDelete clause J2D2 and insert NSW J2D2 as follows: (1) For a Class 3 and 5 to 9 building, Performance Requirement NSW J1P1 is satisfied by complying…
- NSW J4D1 Deemed-to-Satisfy ProvisionsDelete subclause J4D1(1) and insert NSW J4D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1…
- NSW J4D2 Application of PartDelete clause J4D2 and insert NSW J4D2 as follows: The Deemed-to-Satisfy Provisions of this Part apply to building elements forming the envelope of…
- NSW J5D1 Deemed-to-Satisfy ProvisionsDelete subclause J5D1(1) and insert NSW J5D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1…
- NSW J5D2 Application of PartDelete clause J5D2 and insert NSW J5D2 as follows: The Deemed-to-Satisfy Provisions of this Part apply to elements forming the envelope of a Class 3…
- NSW J6D1 Deemed-to-Satisfy ProvisionsDelete subclause J6D1(1) and insert NSW J6D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1…
- NSW J6D3 Air-conditioning system controlDelete subclause J6D3(5) and insert NSW J6D3(5) as follows: (5) The requirements of (3) and (4) do not apply to— an air-conditioning system that…
- NSW J6D4 Mechanical ventilation system controlDelete subclause J6D4(1) and insert NSW J6D4(1) as follows: (1) A mechanical ventilation system, including one that is part of an air-conditioning…
- NSW J6D12 Unitary air-conditioning equipmentDelete subclause J6D12(5) and insert NSW J6D12(5) as follows: (5) The requirements of (2) to (4) do not apply to unitary air-conditioners with a…
- NSW J7D1 Deemed-to-Satisfy ProvisionsDelete subclause J7D1(1) and insert NSW J7D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1…
- NSW J7D3 Artificial lightingDelete subclause J7D3(1) and insert NSW J7D3(1) as follows: (1) This subclause does not apply in NSW. Delete subclause J7D3(2) and insert NSW…
- NSW J7D4 Interior artificial lighting and power controlDelete subclause J7D4(1) and insert NSW J7D4(1) as follows: (1) This subclause does not apply in NSW. Delete subclause J7D4(2) and insert NSW…
- NSW J8D1 Deemed-to-Satisfy ProvisionsDelete subclause J8D1(1) and insert NSW J8D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1…
- NSW J8D2 Application of PartDelete clause J8D2 and insert NSW J8D2 as follows: The Deemed-to-Satisfy Provisions of this Part apply to a Class 3 and Class 5 to 9 building.
- NSW J9D1 Deemed-to-Satisfy ProvisionsDelete subclause J9D1(1) and insert NSW J9D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1…
- NSW J9D2 Application of PartDelete clause J9D2 and insert NSW J9D2 as follows: The Deemed-to-Satisfy Provisions of this Part do not apply to a Class 8 electricity network…
- NSW Part F8 Condensation managementThis Part has been deliberately left blank. Part F8 of NCC 2025 Volume One does not apply in NSW and Part F8 of NCC 2022 Amendment 2 Volume One…
- NSW Part G7 Livable housing designThis Part has deliberately been left blank. Part G7 does not apply in NSW as livable housing design requirements do not apply to sole-occupancy…
- NSW Part J3 Elemental provisions for a Class 4 part of a buildingThis Part has deliberately been left blank. Section J of NCC 2025 Volume One does not apply to a Class 4 part of building in NSW.
- NSW S7C4 Wall and ceiling liningsDelete clause S7C4 and insert NSW S7C4 as follows: (1) A wall or ceiling lining system must comply with the group number specified in Table S7C4 and…
- NSW S20C8 System monitoringDelete clause S20C8 and insert NSW S20C8 as follows: The following installations must be connected to a fire alarm monitoring system connected to a…
- NSW S43C2 Separation from classified vegetationThis clause has deliberately been left blank. S43C2 does not apply in NSW as minimum distances for an Asset Protection Zone must be determined in…
- NSW S43C11 Supply of water for fire-fighting purposesDelete clause S43C11 and insert NSW S43C11 as follows: Water for fire-fighting purposes must be available and consist of— A fire hydrant system…