New South Wales variation · NCC 2025 Volume One

NSW G5O1 Objective

NSW Part G5 Construction in bushfire prone areas · varies G5O1 Objective

Open on NCC Online ↗

Delete clause G5O1 and insert NSW G5O1 as follows:

The Objective of this Part is to—

safeguard occupants from injury from the effects of a bushfire; and

protect buildings from the effects of a bushfire; and

facilitate temporary shelter for building occupants who may be unable to readily evacuate the building prior to a bushfire.

Applications

NSW G5O1(a) and (b) apply in a designated bushfire prone area to—

a Class 2 or 3 building; or

a Class 4 part of a building; or

a Class 10a building or deck associated with a Class 2 or 3 building, or a Class 4 part of a building.

NSW G5O1(a), (b) and (c) apply in a designated bushfire prone area to—

a Class 9 building that is a special fire protection purpose; and

a Class 10a building or deck immediately adjacent or connected to a building of a type listed in (a).

New in NCC 2025. No NSW G5O1 in NCC 2022 Volume One; it may have moved or been renumbered.