New South Wales variation · NCC 2025 Volume One

NSW I4D24 Seating in rows: platforms and steps

NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres

Open on NCC Online ↗

Delete clause I4D24 and insert NSW I4D24 as follows:

Where an aisle contains platforms or steps—

the platforms and steps must extend for the full width of the aisle; and

if there are no intervening steps between levels of platforms, the height of the platform riser must not be more than 200 mm; and

if there are one or more intervening steps between the levels of platforms—

each riser must be at least 100 mm but not more than 200 mm high; and

each going must be at least 250 mm deep; and

risers and goings must be uniform; and

goings which are more than 450 mm deep at platform level must have a grade of not more than 1 in 50; and

at the entrance from the aisle to each row there must be a clear level floor space, extending the full width of the aisle, of at least 300 mm, measured from the back of the row in front; and

any going projecting in front of a seat adjacent to an aisle must be protected by a guardrail.

Changed since NCC 2022. See NCC 2022 Volume One NSW I4D24, or show what changed.

Delete clause I4D24 and insert NSW I4D24 as follows: Where an aisle contains platforms or steps — the platforms … adjacent to an aisle must be protected by a guardrail.

Removed words are struck through; added words are highlighted. Comparison of the text only.