New South Wales variation · NCC 2025 Volume One

NSW I4D25 Seating in rows: stepped platforms

NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres

Open on NCC Online ↗

Delete clause I4D25 and insert NSW I4D25 as follows:

Where stepped platforms without chairs or stepped platforms with bench seats, are used for seating—

each platform must be at least 700 mm deep; and

each seating space must be at least 450 mm wide, measured along the front of the platform or bench seat; and

each seating space must be numbered consecutively; and

at the entrance from the aisle to each row there must be a clear level floor space, extending the full width of the aisle, of at least 300 mm, measured from the back of the row in front; and

any going projecting in front of a seat adjacent to an aisle must be protected by a guardrail; and

in the case of stepped platforms with bench seats, there must be at least 300 mm between the back of each seat and the front of the platform behind, or the front of the bench seat behind, whichever is the closer.

Changed since NCC 2022. See NCC 2022 Volume One NSW I4D25, or show what changed.