New South Wales variation · NCC 2025 Volume One

NSW I4D42 Guardrails for seating areas: cross-overs

NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres

Open on NCC Online ↗

Delete clause I4D42 and insert NSW I4D42 as follows:

A guardrail provided along the front edge of a cross-over on a stepped floor—

must be at least 750 mm high; and

must extend the full distance between aisles, or between a wall and an aisle, or for such other distance as considered necessary.

Changed since NCC 2022. See NCC 2022 Volume One NSW I4D42, or show what changed.

Delete clause I4D42 and insert NSW I4D42 as follows: A guardrail provided along the front edge of a cross-over … an aisle, or for such other distance as considered necessary.

Removed words are struck through; added words are highlighted. Comparison of the text only.