S37C3 U-Value — Method 1 (Single Aspect)
Specification 37 Calculation of U-Value and solar admittance · NCC 2019: Spec J1.5a: 3
(1) For the purposes of this method, a wall-glazing construction only includes the walls and glazing facing a single aspect.
(2) The Total System U-Value of the wall component of a wall-glazing construction must be calculated as the inverse of the Total R-Value, including allowance for thermal bridging, in accordance with—
AS/NZS 4859.2; or
Specification 38 for spandrel panels.
(3) The Total System U-Value of a wall-glazing construction must be calculated as the area-weighted average of the Total System U-Value of each of the components of the wall-glazing construction.
Changed since NCC 2022. See NCC 2022 Volume One S37C3, or show what changed.
(1) For the purposes of this method, a wall-glazing construction … U-Value of each of the components of the wall-glazing construction. (4) The Total System U-Value must not exceed the applicable value in J4D6(1).