NCC 2025 Volume One
Specification 37 Calculation of U-Value and solar admittance
14 clauses · Open on NCC Online ↗
- S37C1 ScopeThis specification describes the methods of calculating the U-Value and solar admittance of a wall-glazing construction.
- S37C2 GeneralFor determining the aspect of a wall-glazing construction — the northern aspect is within 45° of true north; and the southern aspect is within 45°…
- S37C3 U-Value — Method 1 (Single Aspect)For the purposes of this method, a wall-glazing construction only includes the walls and glazing facing a single aspect. (2) The Total System…
- S37C4 U-Value — Method 2 (Multiple Aspects)For the purposes of this method, a wall-glazing construction only includes the walls and glazing facing multiple aspects. (2) The Total System…
- S37C5 Solar admittance — Method 1 (Single Aspect)The solar admittance of a wall-glazing construction must be calculated in accordance with the following formula: [formula] (2) In the formula at…
- Table S37C6a Solar admittance weighting coefficient — Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward areaAspect | Climate zone 1 | Climate zone 2 | Climate zone 3 | Climate zone 4 | Climate zone 5 | Climate zone 6 | Climate zone 7 | Climate zone 8…
- Table S37C6b Solar admittance weighting coefficient — Class 3 or 9c building or Class 9a ward areaAspect | Climate zone 1 | Climate zone 2 | Climate zone 3 | Climate zone 4 | Climate zone 5 | Climate zone 6 | Climate zone 7 | Climate zone 8…
- S37C6 Solar admittance — Method 2 (Multiple Aspects)The solar admittance of wall-glazing construction must achieve a representative air-conditioning energy value less than that achieved by the…
- Table S37C7a Horizontal shading multipliers — Northern, eastern and western aspectsG/H | P/H = 0 | P/H = 0.1 | P/H = 0.2 | P/H = 0.3 | P/H = 0.4 | P/H = 0.5 | P/H = 0.6 | P/H = 0.7 | P/H = 0.8 | P/H = 0.9 | P/H = 1 0 | 1.00 | 0.90…
- Table S37C7b Horizontal shading multipliers — Southern aspectG/H | P/H = 0 | P/H = 0.1 | P/H = 0.2 | P/H = 0.3 | P/H = 0.4 | P/H = 0.5 | P/H = 0.6 | P/H = 0.7 | P/H = 0.8 | P/H = 0.9 | P/H = 1 0 | 1.00 | 0.93…
- Table S37C7c Vertical shading multipliers — Northern aspectClimate zone | D | W = 1.7 H | W = H | W = 0.7 H | W = 0.5 H 1, 2, 3, 5, 6 | 0.1 W | 0.91 | 0.90 | 0.90 | 0.90 1, 2, 3, 5, 6 | 0.3 W | 0.85 | 0.83 |…
- Table S37C7d Vertical shading multipliers — Western aspectClimate zone | D | W = 1.7 H | W = H | W = 0.7 H | W = 0.5 H 1, 2, 3, 5, 6 | 0.1 W | 0.93 | 0.91 | 0.90 | 0.90 1, 2, 3, 5, 6 | 0.3 W | 0.87 | 0.85 |…
- Table S37C7e Vertical shading multipliers — Eastern aspectClimate zone | D | W = 1.7 H | W = H | W = 0.7 H | W = 0.5 H 1, 2, 3, 5, 6 | 0.1 W | 0.94 | 0.94 | 0.93 | 0.93 1, 2, 3, 5, 6 | 0.3 W | 0.90 | 0.89 |…
- S37C7 ShadingFor the purpose of calculating solar admittance, the shading multiplier for each glazing element is the lesser of— for shading provided by an…