Specification clause · NCC 2025 Volume One

S38C2 Spandrel panel R-Value: Calculation method 1

Specification 38 Spandrel panel thermal performance · NCC 2019: Spec J1.5b: 2

Open S38C2 on NCC Online ↗

Spandrel panels are deemed to have the thermal properties nominated in Table S38C2, where—

Configuration 1 consists of—

a thermally unbroken (bridged) frame; and

a centre of spandrel panel consisting of—

a single-glazed opaque or clear face; and

a 100 mm air gap; and

a 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan; and

Configuration 2 consists of—

a thermally unbroken (bridged) frame; and

a centre of spandrel panel consisting of—

a double-glazed opaque face; and

a 50 mm air gap; and

a 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan; and

Configuration 3 consists of—

a thermally broken (unbridged) frame; and

a centre of spandrel panel consisting of—

a double-glazed clear face; and

a 50 mm air gap; and

a 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan; and

Configuration 4 consists of—

a thermally broken (unbridged) frame; and

a centre of spandrel panel consisting of—

a double-glazed low-e clear face; and

a 50 mm air gap; and

a 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan.

Table S38C2 Achieved Total R-Value of spandrel panels

Type

No insulation

R0.5 insulation

R1.0 insulation

R1.5 insulation

R2.0 insulation

Configuration 1

0.3

0.39

0.42

0.44

0.45

Configuration 2

0.35

0.41

0.43

0.44

0.45

Configuration 3

0.84

0.96

1.03

1.07

1.09

Configuration 4

0.91

1.00

1.05

1.09

1.11

Tables

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One S38C2.

Defined terms used