South Australia variation · NCC 2025 Volume One
SA I3D3 Provision for escape
SA Part I3 Farm buildings and farm sheds · varies I3D3 Provision for escape
Delete clause I3D3 and insert SA I3D3 as follows:
(1) Exit travel distances in a farm building must comply with D2D5 except—
no point on the floor must be more than 20 m from an exit, or a point from which travel in different directions to 2 exits is available, in which case the maximum distance to one of those exits must not exceed 60 m; and
in a machinery room, plant room or the like, the distance to a single exit serving a storey at the level of access to a road or open space may be increased to 30 m.
(2) Exits that are required as alternative means of egress in a farm building must be in accordance with D2D6 except they must not be more than 80 m apart.
New in NCC 2025. No SA I3D3 in NCC 2022 Volume One; it may have moved or been renumbered.