South Australia variation · NCC 2025 Volume One

SA I3D3 Provision for escape

SA Part I3 Farm buildings and farm sheds · varies I3D3 Provision for escape

Open on NCC Online ↗

Delete clause I3D3 and insert SA I3D3 as follows:

(1) Exit travel distances in a farm building must comply with D2D5 except—

no point on the floor must be more than 20 m from an exit, or a point from which travel in different directions to 2 exits is available, in which case the maximum distance to one of those exits must not exceed 60 m; and

in a machinery room, plant room or the like, the distance to a single exit serving a storey at the level of access to a road or open space may be increased to 30 m.

(2) Exits that are required as alternative means of egress in a farm building must be in accordance with D2D6 except they must not be more than 80 m apart.

New in NCC 2025. No SA I3D3 in NCC 2022 Volume One; it may have moved or been renumbered.

The national clause