Table · NCC 2025 Volume One

Table D4D10 Wheelchair seating spaces in Class 9b assembly buildings

Part D4 Access for people with a disability

Open Table D4D10 on NCC Online ↗
Fixed seats in a room or spaceWheelchair spaces Note 1Grouping and locationSpaces must represent range of seating provided Note 3
Minimum spaces required1 additional space required per Note 2Min. single spacesMin. groups of 2 spacesMax. spaces in any other group
Up to 1503N/A11N/ANo
151 to 800350 seats in excess of 150 seats115No
801 to 10 00016100 seats in excess of 800 seats225Yes
More than 10 000108200 seats in excess of 10 000 seats5510Yes

Table Notes

The total number of required wheelchair spaces is the sum of the minimum spaces required (left column) and the additional spaces required (right column).

The first number referred to includes any part of that number (e.g. 1 additional space required per 50 seats or part thereof).

This means that the location of required wheelchair spaces must be representative of the range of seating provided.

Table for D4D10 Wheelchair seating spaces in Class 9b assembly buildings

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table D4D10.

Defined terms used