NCC 2025 Volume One
Part D4 Access for people with a disability
16 clauses · Open on NCC Online ↗
- D4D1 Deemed-to-Satisfy Provisions NSW TASWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to D1P6, D1P8 and D1P10 are satisfied by complying with— D2D2 to…
- Table D4D2a Requirements for access for people with a disability – sole-occupancy units in a Class 1b buildingTotal number of dwellings | Number required to be accessible 4 to 10 | 1 11 to 40 | 2 41 to 60 | 3 61 to 80 | 4 81 to 100 | 5 More than 100 | 5…
- Table D4D2b Requirements for access for people with a disability – sole-occupancy units in a Class 3 or 9c buildingTotal number of sole-occupancy units | Number required to be accessible 1 to 10 | 1 11 to 40 | 2 41 to 60 | 3 61 to 80 | 4 81 to 100 | 5 101 to 200…
- D4D2 General building access requirements SABuildings and parts of buildings must be accessible as required by this clause, unless exempted by D4D5. (2) Access requirements for a Class 1b…
- D4D3 Access to buildingsAn accessway must be provided to a building required to be accessible — from the main points of a pedestrian entry at the allotment boundary; and…
- D4D4 Parts of buildings to be accessibleIn a building required to be accessible — every ramp and stairway, except for ramps and stairways in areas exempted by D4D5, must comply with— for a…
- D4D5 Exemptions SA TASThe following areas are not required to be accessible: An area where access would be inappropriate because of the particular purpose for which the…
- D4D6 Accessible carparkingAccessible carparking spaces— subject to (b), must be provided in accordance with (2) in— a Class 7a building required to be accessible; and a…
- D4D7 SignageIn a building required to be accessible — braille and tactile signage complying with Specification 15 must— incorporate the international symbol of…
- D4D8 Hearing augmentationA hearing augmentation system must be provided where an inbuilt amplification system, other than one used only for emergency warning, is installed—…
- D4D9 Tactile indicatorsFor a building required to be accessible, tactile ground surface indicators must be provided to warn people who are blind or have a vision…
- Table D4D10 Wheelchair seating spaces in Class 9b assembly buildingsFixed seats in a room or space | Wheelchair spaces Note 1 | Grouping and location | Spaces must represent range of seating provided Note 3 Minimum…
- D4D10 Wheelchair seating spaces in Class 9b assembly buildingsWhere fixed seating is provided in a Class 9b assembly building, wheelchair seating spaces complying with AS 1428.1 must be provided in accordance…
- D4D11 Swimming poolsNot less than 1 means of accessible water entry/exit in accordance with Specification 16 must be provided for each swimming pool required by D4D2 to…
- D4D12 RampsOn an accessway — a series of connected ramps must not have a combined vertical rise of more than 3.6 m; and a landing for a step ramp must not…
- D4D13 Glazing on an accesswayOn an accessway, where there is no chair rail, handrail or transom, all frameless or fully glazed doors, sidelights and any glazing capable of being…