Table · NCC 2025 Volume One

Table J3D11b Orientation sector winter exposure factor (EW): climate zone 2

Part J3 Elemental provisions for a Class 4 part of a building

Open Table J3D11b on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.491.611.230.960.681.031.371.71
0.051.441.531.140.810.570.901.271.64
0.101.381.481.090.760.530.851.221.55
0.201.211.320.970.690.500.751.101.39
0.401.001.060.770.570.420.630.921.14
0.600.830.870.690.500.370.550.770.96
0.800.620.690.560.430.350.500.660.79
1.000.430.590.460.410.330.430.560.65
1.200.260.470.400.360.310.400.530.53
1.400.220.400.330.330.290.380.470.44
1.600.180.320.310.330.280.350.390.39
1.800.150.280.270.310.260.330.350.32
2.000.120.210.240.290.260.330.330.31

Table for J3D11 External winter glazing of a Class 4 part of a building

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D11b.