Table · NCC 2025 Volume One

Table J3D11f Orientation sector winter exposure factor (EW): climate zone 6

Part J3 Elemental provisions for a Class 4 part of a building

Open Table J3D11f on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.003.042.501.521.511.511.631.762.75
0.052.942.361.391.281.261.381.622.61
0.102.912.281.331.211.191.301.522.55
0.202.502.051.181.081.051.161.402.34
0.402.291.771.010.910.910.981.201.98
0.601.951.510.860.770.810.831.041.71
0.801.731.280.720.710.740.800.921.42
1.001.381.020.650.640.670.690.781.24
1.201.120.950.550.610.600.650.721.04
1.400.850.720.490.540.600.620.640.93
1.600.700.650.420.500.560.540.560.79
1.800.510.530.400.470.530.510.540.72
2.000.400.470.380.440.490.510.480.58

Table for J3D11 External winter glazing of a Class 4 part of a building

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D11f.