Table · NCC 2025 Volume One

Table J3D11g Orientation sector winter exposure factor (EW): climate zones 7 and 8

Part J3 Elemental provisions for a Class 4 part of a building

Open Table J3D11g on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.661.530.900.820.740.780.831.43
0.051.611.470.830.690.610.660.761.37
0.101.611.440.790.640.590.620.731.34
0.201.511.340.730.580.530.550.661.22
0.401.301.170.630.490.440.470.551.07
0.601.191.020.540.430.400.410.480.91
0.801.020.880.480.390.360.370.430.79
1.000.930.780.440.340.340.330.370.67
1.200.730.660.370.320.320.310.330.60
1.400.660.640.360.300.290.290.300.46
1.600.510.460.320.280.270.250.280.43
1.800.420.440.260.260.270.250.250.37
2.000.310.370.260.240.250.250.220.31

Table for J3D11 External winter glazing of a Class 4 part of a building

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D11g.