Table · NCC 2025 Volume One

Table J3D12f Orientation sector summer exposure factor (Es) — climate zone 5

Part J3 Elemental provisions for a Class 4 part of a building

Open Table J3D12f on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.821.201.311.060.821.041.301.16
0.050.691.061.180.940.680.921.191.04
0.100.630.971.110.870.650.861.110.94
0.200.510.840.980.770.580.760.990.83
0.400.390.640.780.630.460.620.810.62
0.600.350.510.640.520.400.510.650.48
0.800.300.410.550.440.340.430.520.40
1.000.260.340.460.370.300.370.460.31
1.200.240.290.400.330.260.330.400.27
1.400.210.250.350.300.240.290.340.24
1.600.200.240.320.250.220.270.300.21
1.800.180.220.280.230.200.230.270.20
2.000.170.190.260.230.190.210.250.19

Table for J3D12 External summer glazing of a Class 4 part of a building

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table J3D12f.