Deemed-to-Satisfy Provision · NCC 2025 Volume One

J3D12 External summer glazing of a Class 4 part of a building

Part J3 Elemental provisions for a Class 4 part of a building

Open J3D12 on NCC Online ↗

(1) In climate zones 1 to 7, the aggregate solar heat gain of the glazing in each storey, including any mezzanine, of a Class 4 part of a building must—

not exceed the allowance resulting from multiplying the floor area of the storey, including any mezzanine, measured within the enclosing walls, by the constant CSHGC obtained from Table J3D12a; and

be calculated in accordance with the following formula:

[formula] (2) In the formula at (1)(b)—

[formula] = the area of each glazing element; and

[formula] = the Total System SHGC for each glazing element, not exceeding 0.7; and

[formula] = the summer exposure factor for each glazing element obtained from Table J3D12b, J3D12c, J3D12d, J3D12e, J3D12f, J3D12g or J3D12h.

[formula] = the factor obtained from Table J3D12i or Table J3D12j for each glazing element located in a bedroom or room which is not a conditioned space; and

[formula] = the frame factor obtained from Table J3D12i or Table J3D12j for glazing element; and

[formula] = the floor factor obtained from Table J3D12i or Table J3D12j for each glazing element.

(3) For the purpose of J3D12—

orientation sectors must be determined in accordance with Figure 13.3.2a of the ABCB Housing Provisions; and

P/H must be determined in accordance with Figure S37C7a; and

for P/H between those shown in Tables J3D12b, J3D12c, J3D12d, J3D12e, J3D12f, J3D12g, J3D12h, J3D12i and J3D12j, either use the next highest P/H or interpolate.

Table J3D12a Constant for Solar Heat Gain (CSHGC) — climate zones 1 to 7

% Ventilation opening area per m2

Climate zone 1

Climate zone 2

Climate zone 3

Climate zone 4

Climate zone 5

Climate zone 6

Climate zone 7

5% to <10%

0.0191

0.0245

0.0547

0.0506

0.0674

0.1472

0.0930

10% to <15%

0.0237

0.0532

0.0745

0.0946

0.1111

0.2969

0.2405

15% to <20%

0.0294

0.0700

0.0861

0.1203

0.1367

0.3845

0.3267

20% to 90%

0.0364

0.0819

0.0943

0.1385

0.1548

0.4466

0.3879

Table Notes

The ventilation opening area is the total area of each ventilation opening divided by the floor area of the storey, including any mezzanine.

No window can have a design ventilation opening greater than 90% because the window frame will always obstruct some area of the opening.

Interpolation is allowed for values between those shown.

Table J3D12b Orientation sector summer exposure factor (Es) — climate zone 1

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.62

0.76

0.79

0.75

0.52

0.89

1.06

0.85

0.05

0.52

0.67

0.73

0.68

0.45

0.82

0.98

0.75

0.10

0.49

0.61

0.68

0.65

0.41

0.76

0.92

0.69

0.20

0.44

0.53

0.62

0.57

0.33

0.66

0.80

0.60

0.40

0.36

0.41

0.48

0.42

0.25

0.53

0.66

0.47

0.60

0.30

0.33

0.40

0.36

0.20

0.42

0.53

0.38

0.80

0.26

0.28

0.32

0.28

0.18

0.36

0.46

0.32

1.00

0.23

0.23

0.27

0.25

0.15

0.30

0.38

0.28

1.20

0.21

0.21

0.23

0.20

0.13

0.27

0.34

0.26

1.40

0.20

0.19

0.20

0.18

0.13

0.22

0.30

0.22

1.60

0.18

0.16

0.17

0.16

0.11

0.20

0.27

0.21

1.80

0.15

0.16

0.16

0.13

0.10

0.20

0.24

0.18

2.00

0.14

0.15

0.14

0.13

0.10

0.17

0.22

0.17

Table J3D12c Orientation sector summer exposure factor (Es) — climate zone 2

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.65

1.16

1.59

1.20

0.73

1.30

1.77

1.23

0.05

0.54

1.01

1.43

1.06

0.61

1.18

1.62

1.10

0.10

0.50

0.94

1.35

0.99

0.58

1.10

1.50

1.00

0.20

0.42

0.81

1.20

0.88

0.51

0.98

1.32

0.87

0.40

0.35

0.62

0.95

0.70

0.40

0.78

1.10

0.67

0.60

0.30

0.48

0.78

0.57

0.33

0.64

0.88

0.50

0.80

0.26

0.41

0.65

0.47

0.29

0.54

0.77

0.43

1.00

0.23

0.33

0.56

0.40

0.24

0.47

0.62

0.36

1.20

0.21

0.30

0.46

0.35

0.22

0.40

0.54

0.31

1.40

0.19

0.26

0.42

0.32

0.21

0.35

0.48

0.27

1.60

0.17

0.25

0.36

0.29

0.19

0.31

0.41

0.24

1.80

0.15

0.22

0.31

0.25

0.17

0.30

0.37

0.22

2.00

0.15

0.21

0.29

0.24

0.16

0.26

0.36

0.21

Table J3D12d Orientation sector summer exposure factor (Es) — climate zone 3

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.80

1.26

1.41

1.38

0.89

1.33

1.29

1.20

0.05

0.67

1.14

1.31

1.26

0.77

1.21

1.20

1.07

0.10

0.63

1.03

1.24

1.19

0.73

1.14

1.13

0.99

0.20

0.54

0.88

1.09

1.05

0.62

1.00

1.01

0.87

0.40

0.46

0.68

0.87

0.83

0.51

0.83

0.80

0.67

0.60

0.40

0.52

0.73

0.68

0.42

0.66

0.67

0.52

0.80

0.34

0.42

0.58

0.55

0.36

0.58

0.57

0.42

1.00

0.29

0.35

0.50

0.47

0.32

0.49

0.50

0.35

1.20

0.27

0.31

0.42

0.40

0.28

0.43

0.41

0.31

1.40

0.24

0.27

0.35

0.36

0.27

0.37

0.39

0.27

1.60

0.24

0.24

0.33

0.32

0.22

0.36

0.33

0.25

1.80

0.21

0.23

0.30

0.28

0.22

0.32

0.31

0.23

2.00

0.21

0.22

0.25

0.28

0.20

0.28

0.26

0.20

Table J3D12e Orientation sector summer exposure factor (Es) — climate zone 4

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.79

1.13

1.12

1.05

0.68

1.14

1.44

1.23

0.05

0.67

1.05

1.05

0.97

0.59

1.05

1.34

1.12

0.10

0.62

0.95

0.99

0.91

0.55

0.98

1.29

1.03

0.20

0.47

0.83

0.90

0.82

0.49

0.87

1.16

0.89

0.40

0.33

0.63

0.74

0.67

0.41

0.71

0.94

0.68

0.60

0.30

0.48

0.59

0.56

0.35

0.61

0.79

0.50

0.80

0.26

0.36

0.50

0.49

0.30

0.52

0.65

0.40

1.00

0.22

0.29

0.44

0.42

0.26

0.45

0.56

0.33

1.20

0.21

0.25

0.37

0.37

0.24

0.40

0.50

0.28

1.40

0.18

0.22

0.31

0.34

0.20

0.38

0.42

0.23

1.60

0.18

0.19

0.30

0.30

0.19

0.33

0.36

0.22

1.80

0.15

0.17

0.26

0.27

0.17

0.29

0.35

0.19

2.00

0.14

0.16

0.22

0.23

0.17

0.28

0.29

0.18

Table J3D12f Orientation sector summer exposure factor (Es) — climate zone 5

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.82

1.20

1.31

1.06

0.82

1.04

1.30

1.16

0.05

0.69

1.06

1.18

0.94

0.68

0.92

1.19

1.04

0.10

0.63

0.97

1.11

0.87

0.65

0.86

1.11

0.94

0.20

0.51

0.84

0.98

0.77

0.58

0.76

0.99

0.83

0.40

0.39

0.64

0.78

0.63

0.46

0.62

0.81

0.62

0.60

0.35

0.51

0.64

0.52

0.40

0.51

0.65

0.48

0.80

0.30

0.41

0.55

0.44

0.34

0.43

0.52

0.40

1.00

0.26

0.34

0.46

0.37

0.30

0.37

0.46

0.31

1.20

0.24

0.29

0.40

0.33

0.26

0.33

0.40

0.27

1.40

0.21

0.25

0.35

0.30

0.24

0.29

0.34

0.24

1.60

0.20

0.24

0.32

0.25

0.22

0.27

0.30

0.21

1.80

0.18

0.22

0.28

0.23

0.20

0.23

0.27

0.20

2.00

0.17

0.19

0.26

0.23

0.19

0.21

0.25

0.19

Table J3D12g Orientation sector summer exposure factor (Es) — climate zone 6

P/H

North

North east

East

South east

South

South west

West

North west

0.00

2.18

2.75

2.88

2.22

1.59

2.46

2.91

2.90

0.05

1.85

2.47

2.63

1.99

1.35

2.25

2.70

2.64

0.10

1.69

2.30

2.48

1.89

1.27

2.13

2.60

2.43

0.20

1.35

1.96

2.20

1.66

1.14

1.92

2.33

2.13

0.40

0.94

1.48

1.78

1.38

0.94

1.57

1.87

1.61

0.60

0.78

1.10

1.53

1.15

0.81

1.36

1.58

1.19

0.80

0.68

0.89

1.25

0.97

0.68

1.17

1.37

0.94

1.00

0.57

0.74

1.05

0.82

0.60

0.98

1.16

0.84

1.20

0.52

0.61

0.93

0.74

0.60

0.91

1.00

0.68

1.40

0.47

0.56

0.80

0.66

0.49

0.80

0.87

0.61

1.60

0.42

0.48

0.70

0.61

0.47

0.73

0.79

0.49

1.80

0.39

0.46

0.65

0.56

0.44

0.66

0.71

0.47

2.00

0.36

0.43

0.60

0.54

0.44

0.61

0.64

0.40

Table J3D12h Orientation sector summer exposure factor (Es) — climate zone 7

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.89

1.06

1.06

0.93

0.70

0.91

1.06

1.07

0.05

0.77

0.95

0.97

0.82

0.59

0.81

0.97

0.97

0.10

0.71

0.88

0.92

0.79

0.56

0.76

0.92

0.89

0.20

0.58

0.77

0.82

0.69

0.50

0.68

0.81

0.78

0.40

0.37

0.59

0.67

0.57

0.42

0.55

0.66

0.58

0.60

0.30

0.46

0.57

0.50

0.36

0.47

0.56

0.46

0.80

0.26

0.36

0.48

0.44

0.31

0.41

0.47

0.36

1.00

0.23

0.30

0.42

0.37

0.28

0.35

0.39

0.29

1.20

0.20

0.25

0.36

0.34

0.25

0.31

0.34

0.25

1.40

0.18

0.21

0.32

0.30

0.23

0.28

0.29

0.22

1.60

0.17

0.19

0.29

0.27

0.22

0.26

0.28

0.19

1.80

0.16

0.18

0.25

0.24

0.20

0.24

0.24

0.17

2.00

0.15

0.17

0.24

0.23

0.20

0.21

0.22

0.16

Table J3D12i Conductance factors — climate zone 1

Factor

Value

Room type multiplier (for bedroom and unconditioned areas) (RS)

0.32

Frame solar absorptance multiplier Frame SA = 0.3 up to 0.4 (FS)

0.83

Frame solar absorptance multiplier Frame SA = 0.4 up to 0.5 (FS)

1.00

Frame solar absorptance multiplier Frame SA = 0.5 or more (FS)

1.20

Floor factor for tiled or vinyl covered floors (HS)

1.00

Floor factor for other than tiled or vinyl covered floors (HS)

1.00

Table J3D12j Conductance factors — climate zones 2 to 7

Type of factor

Climate zone 2

Climate zone 3

Climate zone 4

Climate zone 5

Climate zone 6

Climate zone 7

Room type mul

Tables

Changed since NCC 2022. See NCC 2022 Volume One J3D12, or show what changed.

(1) In climate zones 1 to 7, the aggregate solar heat gain of the glazing in each storey, including any mezzanine, of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building must — not … Provisions; and P/H must be determined in accordance with Figure S37C7; S37C7a; and for P/H between those shown in Tables J3D12b, J3D12c, … zone 2 Climate zone 3 Climate zone 4 Climate zone 5 Climate zone 6 Climate zone 7 Room type mul

Removed words are struck through; added words are highlighted. Comparison of the text only.

Can't meet J3D12? A Performance Solution must meet the Performance Requirements it satisfies: J1P1, J1P2, J1P3, J1P4. Start a Performance Solution →

Defined terms used