Table · NCC 2025 Volume One

Table S35C2h Occupancy and operation profiles of a Class 9b theatre or cinema

Specification 35 Modelling profiles for J1V3

Open Table S35C2h on NCC Online ↗
Time period (local standard time)Occupancy (Monday to Friday)Occupancy (Saturday and Sunday)Artificial lighting (Monday to Friday)Artificial lighting (Saturday and Sunday)Air-conditioning (Monday to Friday)Air-conditioning (Saturday and Sunday)
12:00am to 1:00am0%0%5%5%OffOff
1:00am to 2:00am0%0%5%5%OffOff
2:00am to 3:00am0%0%5%5%OffOff
3:00am to 4:00am0%0%5%5%OffOff
4:00am to 5:00am0%0%5%5%OffOff
5:00am to 6:00am0%0%5%5%OffOff
6:00am to 7:00am0%0%5%5%OffOff
7:00am to 8:00am0%0%5%5%OffOn
8:00am to 9:00am0%20%100%100%OffOn
9:00am to 10:00am0%70%10%10%OffOn
10:00am to 11:00am0%70%10%10%OffOn
11:00am to 12:00pm0%70%10%10%OnOn
12:00pm to 1:00pm20%20%100%100%OnOn
1:00pm to 2:00pm70%70%5%5%OnOn
2:00pm to 3:00pm70%70%5%5%OnOn
3:00pm to 4:00pm70%70%5%5%OnOn
4:00pm to 5:00pm70%70%5%5%OnOn
5:00pm to 6:00pm20%20%100%100%OnOn
6:00pm to 7:00pm20%20%100%100%OnOn
7:00pm to 8:00pm70%70%100%100%OnOn
8:00pm to 9:00pm70%70%5%5%OnOn
9:00pm to 10:00pm70%70%5%5%OnOn
10:00pm to 11:00pm70%70%5%5%OnOn
11:00pm to 12:00am10%10%100%100%OnOn

Table Notes

The occupancy profile is expressed as a percentage of the maximum number of people that can be accommodated in the building.

The artificial lighting profile is expressed as a percentage of the maximum illumination power density permitted under Part J7.

The air-conditioning profile is expressed as the plant status.

Table for S35C2 Modelling profiles

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table S35C2h.

Defined terms used