Table · NCC 2025 Volume One
Table S37C7c Vertical shading multipliers — Northern aspect
Specification 37 Calculation of U-Value and solar admittance
| Climate zone | D | W = 1.7 H | W = H | W = 0.7 H | W = 0.5 H |
|---|---|---|---|---|---|
| 1, 2, 3, 5, 6 | 0.1 W | 0.91 | 0.90 | 0.90 | 0.90 |
| 1, 2, 3, 5, 6 | 0.3 W | 0.85 | 0.83 | 0.82 | 0.81 |
| 1, 2, 3, 5, 6 | 0.5 W | 0.82 | 0.78 | 0.76 | 0.74 |
| 1, 2, 3, 5, 6 | 0.7 W | 0.81 | 0.76 | 0.73 | 0.70 |
| 4 | 0.1 W | 0.91 | 0.91 | 0.90 | 0.90 |
| 4 | 0.3 W | 0.87 | 0.84 | 0.83 | 0.82 |
| 4 | 0.5 W | 0.84 | 0.80 | 0.78 | 0.76 |
| 4 | 0.7 W | 0.83 | 0.78 | 0.75 | 0.73 |
| 7 | 0.1 W | 0.92 | 0.91 | 0.91 | 0.90 |
| 7 | 0.3 W | 0.87 | 0.85 | 0.83 | 0.82 |
| 7 | 0.5 W | 0.86 | 0.82 | 0.79 | 0.78 |
| 7 | 0.7 W | 0.85 | 0.80 | 0.78 | 0.75 |
| 8 | 0.1 W | 0.92 | 0.92 | 0.91 | 0.91 |
| 8 | 0.3 W | 0.90 | 0.88 | 0.86 | 0.85 |
| 8 | 0.5 W | 0.91 | 0.87 | 0.85 | 0.83 |
| 8 | 0.7 W | 0.91 | 0.88 | 0.86 | 0.84 |
Table for S37C7 Shading
New in NCC 2025. No Table S37C7c in NCC 2022 Volume One; it may have moved or been renumbered.