Table · NCC 2025 Volume One

Table S39C2b R-Value of soil in contact with a floor

Specification 39 Sub-floor and soil thermal performance

Open Table S39C2b on NCC Online ↗
Ratio of floor area (m2)  to floor perimeter (m)Wall thickness of 50 mmWall thickness of 100 mmWall thickness of 150 mmWall thickness of 200 mmWall thickness of 250 mmWall thickness of 300 mm
1.00.40.50.50.60.70.8
1.50.60.70.70.80.91.0
2.00.70.80.91.01.11.3
2.50.91.01.11.21.31.5
3.01.01.21.31.41.51.7
3.51.21.31.51.61.71.9
4.01.31.51.61.71.92.2
4.51.51.71.81.92.12.4
5.01.61.82.02.12.32.6
5.51.82.02.12.22.42.8
6.01.92.12.32.42.62.9
6.52.02.32.42.62.83.1
7.02.22.42.62.73.03.3

Table Notes

Where a wall thickness or ratio of floor area to floor perimeter is between the values stated, interpolation may be used to determine the soil R-Value.

Wall thickness means the thickness of the envelope wall that sits on or around the slab.

Table for S39C2 Sub-floor space and soil thermal performance

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table S39C2b.

Defined terms used