Table · NCC 2022 Volume One
Table S39C2b R-Value of soil in contact with a floor
Specification 39 Sub-floor and soil thermal performance
| Ratio of floor area (m2) to floor perimeter (m) | Wall thickness of 50 mm | Wall thickness of 100 mm | Wall thickness of 150 mm | Wall thickness of 200 mm | Wall thickness of 250 mm | Wall thickness of 300 mm |
|---|---|---|---|---|---|---|
| 1.0 | 0.4 | 0.5 | 0.5 | 0.6 | 0.7 | 0.8 |
| 1.5 | 0.6 | 0.7 | 0.7 | 0.8 | 0.9 | 1.0 |
| 2.0 | 0.7 | 0.8 | 0.9 | 1.0 | 1.1 | 1.3 |
| 2.5 | 0.9 | 1.0 | 1.1 | 1.2 | 1.3 | 1.5 |
| 3.0 | 1.0 | 1.2 | 1.3 | 1.4 | 1.5 | 1.7 |
| 3.5 | 1.2 | 1.3 | 1.5 | 1.6 | 1.7 | 1.9 |
| 4.0 | 1.3 | 1.5 | 1.6 | 1.7 | 1.9 | 2.2 |
| 4.5 | 1.5 | 1.7 | 1.8 | 1.9 | 2.1 | 2.4 |
| 5.0 | 1.6 | 1.8 | 2.0 | 2.1 | 2.3 | 2.6 |
| 5.5 | 1.8 | 2.0 | 2.1 | 2.2 | 2.4 | 2.8 |
| 6.0 | 1.9 | 2.1 | 2.3 | 2.4 | 2.6 | 2.9 |
| 6.5 | 2.0 | 2.3 | 2.4 | 2.6 | 2.8 | 3.1 |
| 7.0 | 2.2 | 2.4 | 2.6 | 2.7 | 3.0 | 3.3 |
Table Notes
Where a wall thickness or ratio of floor area to floor perimeter is between the values stated, interpolation may be used to determine the soil R-Value.
Wall thickness means the thickness of the envelope wall that sits on or around the slab.
Table for S39C2 Sub-floor space and soil thermal performance
Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table S39C2b.