Tasmania variation · NCC 2025 Volume One

TAS I13D3 Separation from other areas and buildings

TAS Part I13 Premises for production of processing of isocyanates

Open on NCC Online ↗

Delete clause I13D3 and insert TAS I13D3 as follows:

(1) Each of the divisional areas required by TAS I13D2 other than the administration and staff amenities building, must be—

separated from each of the other divisional areas by means of an impervious wall with an FRL of not less than 120/120/120; or

separated from all other buildings by a clear space of not less than 6 m.

(2) Notwithstanding the distance requirements of (1), bulk stores of polyols and bulk stores of isocyanates must comply with the requirements of the Work Health and Safety Act.

Changed since NCC 2022. See NCC 2022 Volume One TAS I13D3, or show what changed.

Delete clause I13D3 and insert TAS I13D3 as follows: (1) Each of the divisional areas required by TAS I13D2 … with the requirements of the Work Health and Safety Act.

Removed words are struck through; added words are highlighted. Comparison of the text only.