NCC 2025 Volume One
Tasmania variations
141 TAS variations to NCC 2025 Volume One: clauses replaced, added or deleted in Tasmania. Search with TAS variations.
- TAS A1G4 InterpretationInsert TAS subclause A1G4(7) in clause A1G4 as follows: (7) The Director of Building Control may issue written advice to deal with arising issues…
- TAS A5G4 Evidence of suitability ─ Volume Three (PCA)Insert TAS subclause A5G4(7) in clause A5G4 as follows: (7) A product used in roof plumbing, heating ventilation and air-conditioning or on-site…
- TAS D1P10 Standards made under the Disability Discrimination ActInsert TAS clause D1P10 in clause D1P10 as follows: A building or part of a building must be accessible in accordance with the requirements of a…
- TAS D4D1 Deemed-to-Satisfy ProvisionsDelete subclause D4D1(1) and insert TAS D4D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to…
- TAS D4D5 ExemptionsDelete clause D4D5 and insert TAS D4D5 as follows: The following areas are not required to be accessible: An area where access would be…
- TAS D4D14 Compliance with Premises StandardsInsert TAS clause D4D14 in clause D4D14 as follows: (1) A building solution must comply with the Disability (Access to Premises - Buildings)…
- TAS E1D1 Deemed-to-Satisfy ProvisionsDelete clause E1D1 and insert TAS E1D1 as follows: Performance Requirements E1P1 to E1P6 and TAS E1P7 are satisfied by complying with E1D2 to E1D16,…
- TAS E1D17 Fire detection and alarm systemInsert TAS clause E1D17 in clause E1D17 as follows: An automatic fire detection and alarm system must comply with S20C4 and S20C8.
- TAS E1P7 Automatic fire detection systemInsert TAS clause E1P7 in clause E1P7 as follows: An automatic fire detection system must be installed to the degree necessary to alert the fire…
- TAS F4D4 Facilities in Class 3 to 9 buildingsDelete clause F4D4 and insert TAS F4D4 as follows: In Tasmania, clause F4D4 is replaced with clause F4D4 of BCA 2022 Volume One Amendment 2.
- TAS F4D13 Non-flushed urinalsInsert TAS clause F4D13 in clause F4D13 as follows: Non-flushed urinals not connected to a sewerage system must comply with TAS F4D14.
- TAS F4D14 Installation of closet fixturesInsert TAS clause F4D14 in clause F4D14 as follows: (1) If a sufficient sewerage system is not available, an authorised alternative means of…
- TAS F8P1 Condensation and water vapour managementDelete clause F8P1 and insert TAS F8P1 as follows: In a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, risks associated…
- TAS G1D1 Deemed-to-Satisfy ProvisionsDelete subclause G1D1(1) and insert TAS G1D1(1) as follows: (2) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G1P2 to…
- TAS G1D2 Swimming poolsDelete clause G1D2 and insert TAS G1D2 as follows: (1) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2…
- TAS G1P2 Swimming pool access and water recirculation systemsDelete clause G1P2 and insert TAS G1P2 as follows: (1) A barrier must be provided to a swimming pool and must— be continuous for the full extent of…
- TAS G1P6 Swimming poolsInsert TAS clause G1P6 in clause G1P6 as follows: Swimming pools must be suitable and safe to use and be provided with appropriate facilities.…
- TAS G5P1 Bushfire resistanceDelete clause G5P1 and insert TAS G5P1 as follows: A building that is constructed in a designated bushfire prone area must be designed and…
- TAS G5P2 Additional bushfire requirements for certain Class 9 buildingsDelete clause G5P2 and insert TAS G5P2 as follows: A building that is constructed in a designated bushfire prone area and occupied by people who may…
- TAS I4D1 Application of PartDelete clause I4D1 and insert TAS I4D1 as follows: (1) This Part applies to any premises where food intended for human consumption is manufactured,…
- TAS I4D2 Deemed-to-Satisfy ProvisionsDelete clause I4D2 and insert TAS I4D2 as follows: Performance Requirements TAS I4P1 to TAS I4P13 are satisfied by complying with the relevant…
- TAS I4D3 General requirementsDelete clause I4D3 and insert TAS I4D3 as follows: (1) The provision of— close-fitting windows and doors; and air intakes that do not draw in…
- TAS I4D4 Pests and contaminantsDelete clause I4D4 and insert TAS I4D4 as follows: Premises where customers are served outside the premises through an opening, that has an…
- TAS I4D5 Drains and pipesDelete clause I4D5 and insert TAS I4D5 as follows: Premises satisfy TAS I4P4 where— a grease trap, an overflow (relief) gully or an untrapped…
- TAS I4D6 Offensive material and trade wasteDelete clause I4D6 and insert TAS I4D6 as follows: Where offensive material or trade waste is stored, a separate area or room which— is paved and…
- TAS I4D7 VentilationDelete clause I4D7 and insert TAS I4D7 as follows: A mechanical ventilating exhaust system complying with the requirements of AS/NZS 1668.1 and AS…
- TAS I4D8 LightingDelete clause I4D8 and insert TAS I4D8 as follows: A lighting system that— complies with AS 1680.1 and AS/NZS 1680.2.4; and in areas where open food…
- TAS I4D9 Floors, walls and ceilingsDelete clause I4D9 and insert TAS I4D9 as follows: (1) Floors, walls and ceilings constructed in accordance with Section 3 of AS 4674, satisfy TAS…
- TAS I4D10 Separation of work placeDelete clause I4D10 and insert TAS I4D10 as follows: (1) A room where food for sale is processed, manufactured, prepared, deposited, treated, stored…
- TAS I4D11 WashbasinsDelete clause I4D11 and insert TAS I4D11 as follows: (1) Premises or places for preparation or storage of food for sale provided with not less than…
- TAS I4D12 SinksDelete clause I4D12 and insert TAS I4D12 as follows: (1) Where equipment and utensils are required to be manually cleaned and sanitised, or food…
- TAS I4D13 Design, construction and installation of fixtures, fittings and equipmentDelete clause I4D13 and insert TAS I4D13 as follows: (1) The provision of fixtures, fittings and equipment designed, constructed and installed in…
- TAS I4D14 Storage of materials and equipmentDelete clause I4D14 and insert TAS I4D14 as follows: (1) Separate areas for the storage of fuel, cleaning compounds and general maintenance…
- TAS I4D15 Food storeDelete clause I4D15 and insert TAS I4D15 as follows: An eating house provided with a dry-food store, satisfies TAS I4P12.
- TAS I4D16 Meat premisesDelete clause I4D16 and insert TAS I4D16 as follows: Premises used for the preparation or sale of red meat, other than those licensed under the…
- TAS I4D17 Dairy produceDelete clause I4D17 and insert TAS I4D17 as follows: Definition: Dairy produce products include milk, colostrum, liquid milk products, cream and…
- TAS I4D18 Refrigerated and cooling chambersDelete clause I4D18 and insert TAS I4D18 as follows: The construction of a refrigerated chamber or cooling chamber installed in premises for storage…
- TAS I4F1 Food premisesDelete clause I4F1 and insert TAS I4F1 as follows: Each building or part of a building constructed as a food premise must be able to be used in such…
- TAS I4O1 ObjectiveDelete clause I4O1 and insert TAS I4O1 as follows: The objective of this Part is to facilitate the safe manufacture, preparation, storage and…
- TAS I4P1 Application of PartDelete clause I4P1 and insert TAS I4P1 as follows: (1) TAS I4P2 to TAS I4P13 applies to any premises where food intended for human consumption is…
- TAS I4P2 Design and constructionDelete clause I4P2 and insert TAS I4P2 as follows: The design and construction of food premises must— be appropriate for the activities for which…
- TAS I4P3 Water supplyDelete clause I4P3 and insert TAS I4P3 as follows: (1) Food premises must have an adequate supply of water if water is to be used at the food…
- TAS I4P4 Sewage and waste water disposalDelete clause I4P4 and insert TAS I4P4 as follows: Food premises must have a sewage and waste water disposal system that— will effectively dispose…
- TAS I4P5 Storage of garbage and recyclablesDelete clause I4P5 and insert TAS I4P5 as follows: Food premises must have facilities for the storage of garbage and recyclable matter that—…
- TAS I4P6 VentilationDelete clause I4P6 and insert TAS I4P6 as follows: Food premises must have sufficient natural or mechanical ventilation to remove fumes, smoke and…
- TAS I4P7 LightingDelete clause I4P7 and insert TAS I4P7 as follows: Food premises must have lighting systems that provide sufficient natural or artificial light for…
- TAS I4P8 FloorsDelete clause I4P8 and insert TAS I4P8 as follows: (1) Floors must be designed and constructed in a way that is appropriate for the activities…
- TAS I4P9 Walls and ceilingsDelete clause I4P9 and insert TAS I4P9 as follows: Walls and ceilings— must be designed and constructed in a way that is appropriate for the…
- TAS I4P10 Hand washing facilitiesDelete clause I4P10 and insert TAS I4P10 as follows: (1) Food premises must have hand washing facilities that are located where they can be easily…
- TAS I4P11 Fixtures, fittings and equipmentDelete clause I4P11 and insert TAS I4P11 as follows: Fixtures, fittings and equipment must— be adequate for the production of wholesome food; and be…
- TAS I4P12 Storage facilitiesDelete clause I4P12 and insert TAS I4P12 as follows: Food premises must have adequate storage facilities— for the storage of items that are likely…
- TAS I4P13 Refrigerated and cooling chambersDelete clause I4P13 and insert TAS I4P13 as follows: All refrigerated and cooling chambers must be constructed so that the stored products will not…
- TAS I5D1 Application of PartDelete clause I5D1 and insert TAS I5D1 as follows: (1) This Part applies to all dining rooms and bar rooms (excluding bar service areas) on licensed…
- TAS I5D2 Sanitary facilitiesDelete clause I5D2 and insert TAS I5D2 as follows: (1) Separate sanitary facilities for male sand females must be provided in close proximity to…
- TAS I5D3 Separation from other areasDelete clause I5D3 and insert TAS I5D3 as follows: A dining room must not have a direct opening to living quarters, a laundry, bathroom or garage or…
- TAS I6D1 Application of PartDelete clause I6D1 and insert TAS I6D1 as follows: (1) This Part is applicable to— meat premises processing animals, including game and poultry, and…
- TAS I6D2 Premises processing animals and meatDelete clause I6D2 and insert TAS I6D2 as follows: Premises used for the processing of animals and meat for human consumption must comply with the…
- TAS I7D1 Application of PartDelete clause I7D1 and insert TAS I7D1 as follows: (1) This Part is applicable to every farm dairy as covered by the Dairy Industry Act 1994. (2)…
- TAS I7D2 Milking sheds and holding yardsDelete clause I7D2 and insert TAS I7D2 as follows: (1) The walls (including the walls of a pit of a herringbone design milking shed) must be…
- TAS I7D3 Milk receiving area and milk storage roomDelete clause I7D3 and insert TAS I7D3 as follows: (1) A Milk Receiving Area and Milk Storage Room must— have internal surfaces that are smooth,…
- TAS I7D4 Water supplyDelete clause I7D4 and insert TAS I7D4 as follows: An adequate and suitable supply of water must be available for plant sanitation, teat washing,…
- TAS I8D1 Application of PartDelete clause I8D1 and insert TAS I8D1 as follows: (1) This Part applies to all pharmacy business premises registered under the Pharmacy Control…
- TAS I8D2 DefinitionDelete clause I8D2 and insert TAS I8D2 as follows: In this Part the term “dispensary” means the room or area within a pharmacy or other premises…
- TAS I8D3 Pharmacy premisesDelete clause I8D3 and insert TAS I8D3 as follows: (1) Each premises used as a pharmacy must have— a dispensary for the compounding or dispensing of…
- TAS I8D4 DispensaryDelete clause I8D4 and insert TAS I8D4 as follows: (1) A dispensary must be located— within a pharmacy in a position to enable a person in the…
- TAS I8D5 Security of dispensaryDelete clause I8D5 and insert TAS I8D5 as follows: (1) Every dispensary and enclosure set aside for the storage of narcotic substances and poisons…
- TAS I9D1 Application of PartDelete clause I9D1 and insert TAS I9D1 as follows: (1) This Part applies to health service establishments as defined in the Health Service…
- TAS I9D2 Design and construction of health service establishmentsDelete clause I9D2 and insert TAS I9D2 as follows: Every health service establishment must be constructed and maintained in accordance with the…
- TAS I10D1 Application of PartDelete clause I10D1 and insert TAS I10D1 as follows: (1) This Part applies to any premises used for the storage or preparation for burial, cremation…
- TAS I10D2 Layout of mortuaryDelete clause I10D2 and insert TAS I10D2 as follows: (1) A mortuary may be integral with the remainder of a building but must be separated…
- TAS I10D3 Construction of body preparation roomDelete clause I10D3 and insert TAS I10D3 as follows: (1) The floor must be— of impervious material with a smooth, unbroken surface; and uniformly…
- TAS I10D4 Water supply and sewerageDelete clause I10D4 and insert TAS I10D4 as follows: Each mortuary with a body preparation room must be connected to— a permanent water supply with…
- TAS I11D1 Application of PartDelete clause I11D1 and insert TAS I11D1 as follows: (1) This Part is applicable to every building or premises on which foundry operations are…
- TAS I11D2 GeneralDelete clause I11D2 and insert TAS I11D2 as follows: (1) Every floor in a foundry must be level and, in places other than where molten metal is…
- TAS I11D3 Cupola charging platformDelete clause I11D3 and insert TAS I11D3 as follows: (1) The floors of cupola charging platforms must be— of heavy timber or non-slip steel plate;…
- TAS I11D4 Deep moulds and pitsDelete clause I11D4 and insert TAS I11D4 as follows: Deep moulds or pits, for permanent use— must be lined with bricks, concrete, or other suitable…
- TAS I11D5 Pot furnacesDelete clause I11D5 and insert TAS I11D5 as follows: Where pot furnaces are below ground level, the pit must be covered by a substantial grating at…
- TAS I11D6 Hand laminating and spray depositingDelete clause I11D6 and insert TAS I11D6 as follows: The walls and floors of areas to be used for hand laminating and spray depositing must be…
- TAS I12D1 Application of PartDelete clause I12D1 and insert TAS I12D1 as follows: (1) This Part is applicable to every building in which glass reinforced plastics are…
- TAS I12D2 Separation from other buildingsDelete clause I12D2 and insert TAS I12D2 as follows: A building for the manufacture or processing of glass reinforced plastics must be— separated…
- TAS I12D3 Rise in storeysDelete clause I12D3 and insert TAS I12D3 as follows: The building must be of single storey construction.
- TAS I12D4 Maximum floor areasDelete clause I12D4 and insert TAS I12D4 as follows: The floor area of any building or fire-separated section must not exceed the relevant maximum…
- TAS I12D5 Required exitsDelete clause I12D5 and insert TAS I12D5 as follows: (1) Each fire-separated section of a building which is a work place must have at least two…
- TAS I12D7 VentilationDelete clause I12D7 and insert TAS I12D7 as follows: (1) Mechanical or natural ventilation must be via low-level, exhaust ducting in a wall and a…
- TAS I12D8 Smoke and heat roof ventsDelete clause I12D8 and insert TAS I12D8 as follows: Each fire-separated section must be provided with automatic smoke and heat roof vents.
- TAS I13D1 Application of PartDelete clause I13D1 and insert TAS I13D1 as follows: (1) This Part is applicable to every building in which isocyanate production or processing is…
- TAS I13D2 Areas of work placesDelete clause I13D2 and insert TAS I13D2 as follows: Work places in which an isocyanate industry is carried out must be divided into the following…
- TAS I13D3 Separation from other areas and buildingsDelete clause I13D3 and insert TAS I13D3 as follows: (1) Each of the divisional areas required by TAS I13D2 other than the administration and staff…
- TAS I13D4 Rise in storeysDelete clause I13D4 and insert TAS I13D4 as follows: The building must be of single storey construction.
- TAS I13D5 Maximum floor areasDelete clause I13D5 and insert TAS I13D5 as follows: The floor area of any building or fire-separated section must not exceed the area shown in…
- TAS I13D6 Required exitsDelete clause I13D6 and insert TAS I13D6 as follows: (1) Every building and divisional area of a work place must have not less than 2 exits for…
- TAS I13D7 Bulk stores for polyols and isocyanatesDelete clause I13D7 and insert TAS I13D7 as follows: (1) A bulk store for polyols must be constructed from non-combustible materials and have a…
- TAS I13D8 Curing roomDelete clause I13D8 and insert TAS I13D8 as follows: The curing room for the storage of newly produced flexible polyurethane foam must be…
- TAS I14D1 Application of PartDelete clause I14D1 and insert TAS I14D1 as follows: (1) This Part is applicable to every building where any of the processes of electro-plating,…
- TAS I14D2 FloorsDelete clause I14D2 and insert TAS I14D2 as follows: The floor of every plating area must be— so graded as to— permit easy flushing with water; and…
- TAS I14D3 Height of plating areaDelete clause I14D3 and insert TAS I14D3 as follows: Every part of a plating area must be not less than 2.7 m in height— measured from the floor to…
- TAS I14D4 Air spaceDelete clause I14D4 and insert TAS I14D4 as follows: In every plating area there must be not less than 14 m3 of air space for each person employed…
- TAS I14D5 Ceiling constructionDelete clause I14D5 and insert TAS I14D5 as follows: The ceiling of a plating area must be so constructed as to prevent, so far as is practicable,…
- TAS I15D1 Application of PartDelete clause I15D1 and insert TAS I15D1 as follows: (1) This Part is applicable to every building in which lead processes are used. (2) Premises…
- TAS I15D2 FloorsDelete clause I15D2 and insert TAS I15D2 as follows: (1) The floor of every work place where a lead process is used must be— so constructed of…
- TAS I15D3 Height of lead processing areasDelete clause I15D3 and insert TAS I15D3 as follows: Every part of a lead processing area must be not less than 2.7 m in height— where a ceiling is…
- TAS I15D4 Air space and floor spaceDelete clause I15D4 and insert TAS I15D4 as follows: (1) In every lead processing area there must be not less than 14 m3 of air space for each…
- TAS I15D5 Interior of lead processing areasDelete clause I15D5 and insert TAS I15D5 as follows: (1) The inner surfaces of the walls of every lead processing area must be of a smooth material…
- TAS I15D6 Dust collectionDelete clause I15D6 and insert TAS I15D6 as follows: Any areas in which dust-forming lead particles are manipulated, moved or treated must be served…
- TAS I15D7 Isolation of certain processesDelete clause I15D7 and insert TAS I15D7 as follows: Where any process of pasting of electric accumulator plates or drying of paste plates, or…
- TAS I15D8 Drying room shelvesDelete clause I15D8 and insert TAS I15D8 as follows: The racks or shelves provided in any drying room must be not more than 2.6 m from the floor nor…
- TAS I15D9 Washing facilitiesDelete clause I15D9 and insert TAS I15D9 as follows: Washing facilities served with running hot and cold water for the use of all employees engaged…
- TAS I15D10 Change roomsDelete clause I15D10 and insert TAS I15D10 as follows: In every work place in which lead is processed there must be provided two suitable furnished…
- TAS I16D1 Application of PartDelete clause I16D1 and insert TAS I16D1 as follows: This Part applies to early childhood centres and school age care facilities approved under the…
- TAS I16D2 Deemed-to-Satisfy ProvisionsDelete clause I16D2 and insert TAS I16D2 as follows: (1) Performance Requirement TAS I16P1 is satisfied by complying with the relevant provisions of…
- TAS I16F1 Early childhood centres and school age care facilitiesDelete clause I16F1 and insert TAS I16F1 as follows: An early childhood centre and school age care facility must be designed and constructed to…
- TAS I16O1 ObjectiveDelete clause I16O1 and insert TAS I16O1 as follows: The Objective of this Part is to regulate the physical specification of early childhood centres…
- TAS I16P1 Design and constructionDelete clause I16P1 and insert TAS I16P1 as follows: The design and construction of an early childhood centre and school age care facility must to…
- TAS I16P2 Health and amenityDelete clause I16P2 and insert TAS I16P2 as follows: An early childhood centre and school age care facility, must to the degree necessary, have…
- TAS I16P3 Perimeter fencing and barriersDelete clause I16P3 and insert TAS I16P3 as follows: An early childhood centre and school age care facility must to the degree necessary, have…
- TAS I17D1 Application of PartDelete clause I17D1 and insert TAS I17D1 as follows: This Part is applicable to every building where work is undertaken on gas-fuelled vehicles.
- TAS I17D2 Working areasDelete clause I17D2 and insert TAS I17D2 as follows: The working area of a building where work is undertaken on a gas-fuelled vehicle is to be…
- TAS I18D1 Application of PartDelete clause I18D1 and insert TAS I18D1 as follows: This Part only applies to a temporary structure that— is used by the public as a place of…
- TAS I18D2 Deemed-to-Satisfy ProvisionsDelete clause I18D2 and insert TAS I18D2 as follows: Performance Requirements TAS I18P1 to TAS I18P16 are satisfied by complying with the provisions…
- TAS I18D3 AccessDelete clause I18D3 and insert TAS I18D3 as follows: (1) Access for people with disabilities must be provided to and within a temporary structure by…
- TAS I18D4 LightingDelete clause I18D4 and insert TAS I18D4 as follows: (1) Natural or artificial lighting must be provided to all enclosed areas in a temporary…
- TAS I18D5 VentilationDelete clause I18D5 and insert TAS I18D5 as follows: (1) Natural ventilation or mechanical ventilation must be provided to all enclosed areas in a…
- TAS I18D6 ElectricalDelete clause I18D6 and insert TAS I18D6 as follows: All electrical installations in a temporary structure must be installed in accordance with…
- TAS I18D7 Heating appliancesDelete clause I18D7 and insert TAS I18D7 as follows: The installation of a stove, heater or similar appliance in a temporary structure must as far…
- TAS I18P1 Application of PartDelete clause I18P1 and insert TAS I18P1 as follows: TAS I18P2 to TAS I18P16 only apply to a temporary structure that— is used by the public as a…
- TAS I18P2 Safety and serviceabilityDelete clause I18P2 and insert TAS I18P2 as follows: A temporary structure must, to the degree necessary, be capable of sustaining at an acceptable…
- TAS I18P3 Resistance to the spread of fireDelete clause I18P3 and insert TAS I18P3 as follows: The material used in a temporary structure must, to the degree necessary, be capable of…
- TAS I18P4 AccessDelete clause I18P4 and insert TAS I18P4 as follows: (1) Access must be provided, to the degree necessary, to enable safe, equitable and dignified…
- TAS I18P5 ExitsDelete clause I18P5 and insert TAS I18P5 as follows: (1) Exits must be provided to the degree necessary, from a temporary structure to enable the…
- TAS I18P6 Fall preventionDelete clause I18P6 and insert TAS I18P6 as follows: Where a person could fall 1 m or more, due to a sudden change of level within or associated…
- TAS I18P7 LightingDelete clause I18P7 and insert TAS I18P7 as follows: A level of illumination for safe evacuation from a temporary structure in an emergency must be…
- TAS I18P8 Identification of exitsDelete clause I18P8 and insert TAS I18P8 as follows: To facilitate evacuation from a temporary structure suitable signs or other means of…
- TAS I18P9 Fire-fighting equipmentDelete clause I18P9 and insert TAS I18P9 as follows: Fire equipment must be installed in a temporary structure to the degree necessary, to allow the…
- TAS I18P10 Sanitary facilitiesDelete clause I18P10 and insert TAS I18P10 as follows: Sanitary facilities for personal hygiene must be provided in a convenient location associated…
- TAS I18P11 Artificial lightingDelete clause I18P11 and insert TAS I18P11 as follows: (1) A temporary structure must be provided with natural or artificial lighting to enable the…
- TAS I18P12 VentilationDelete clause I18P12 and insert TAS I18P12 as follows: (1) A temporary structure must be provided with a means of ventilation which will maintain…
- TAS I18P13 Electrical servicesDelete clause I18P13 and insert TAS I18P13 as follows: Electrical services must be installed to the degree necessary, to provide a level of safety…
- TAS I18P14 Heating appliancesDelete clause I18P14 and insert TAS I18P14 as follows: Where provided for a temporary structure, a heating appliance and its associated components…
- TAS I18P15 Tiered seatingDelete clause I18P15 and insert TAS I18P15 as follows: A temporary structure of tiered seating must be designed and constructed to the degree…
- TAS I18P16 Safe environmentDelete clause I18P16 and insert TAS I18P16 as follows: A temporary structure must, to the degree necessary, be a safe and hazard free environment…
- TAS Part J3 Elemental provisions for a Class 4 part of a buildingThis Part has deliberately been left blank. This Part is deleted from the BCA in Tasmania. In Tasmania, for a Class 2 building and Class 4 part of a…