Tasmania variation · NCC 2025 Volume One

TAS I15D4 Air space and floor space

TAS Part I15 Premises for lead processing

Open on NCC Online ↗

Delete clause I15D4 and insert TAS I15D4 as follows:

(1) In every lead processing area there must be not less than 14 m3 of air space for each person employed therein, and in the calculation of such space the maximum height taken must be not greater than 4.2 m.

(2) The total floor space for the persons employed in such area, exclusive of space used for storage, must be not less than 3.3 m2 for each person so employed.

Changed since NCC 2022. See NCC 2022 Volume One TAS I15D4, or show what changed.

Delete clause I15D4 and insert TAS I15D4 as follows: (1) In every lead processing area there must be not … not less than 3.3 m2 for each person so employed.