TAS I18P14 Heating appliances
TAS Part I18 Temporary structures
Delete clause I18P14 and insert TAS I18P14 as follows:
Where provided for a temporary structure, a heating appliance and its associated components must be installed to the degree necessary—
to withstand the temperatures likely to be generated by the appliance; and
so that it does not raise the temperature of any structural element to a level that would adversely affect the element’s physical or mechanical properties or function; and
so that hot products of combustion will not—
escape through the walls of the associated components; and
discharge to a position that will cause fire to spread to nearby combustible materials or allow smoke to penetrate the temporary structure; and
to reduce the likelihood of fire and harmful emissions spreading beyond the appliance.
Changed since NCC 2022. See NCC 2022 Volume One TAS I18P14, or show what changed.
Delete clause I18P14 and insert TAS I18P14 as follows: Where provided for a temporary structure, a heating appliance and … likelihood of fire and harmful emissions spreading beyond the appliance.
Removed words are struck through; added words are highlighted. Comparison of the text only.