TAS I18P6 Fall prevention
TAS Part I18 Temporary structures
Delete clause I18P6 and insert TAS I18P6 as follows:
Where a person could fall 1 m or more, due to a sudden change of level within or associated with a temporary structure, a barrier must to the degree necessary, be provided which must be—
continuous and extend for the full extent of the hazard; and
of a height to protect people from accidentally falling from the level; and
constructed to prevent people falling through the barrier; and
capable of restricting the passage of children; and
of a strength and rigidity to withstand the foreseeable impact of people and where appropriate, the static pressure or people pressing against it.
Changed since NCC 2022. See NCC 2022 Volume One TAS I18P6, or show what changed.
Delete clause I18P6 and insert TAS I18P6 as follows: Where a person could fall 1 m or more, due … where appropriate, the static pressure or people pressing against it.
Removed words are struck through; added words are highlighted. Comparison of the text only.