TAS I4D12 Sinks
TAS Part I4 Food premises
Delete clause I4D12 and insert TAS I4D12 as follows:
(1) Where equipment and utensils are required to be manually cleaned and sanitised, or food preparation requires a sink, premises that are provided with a suitably sized double bowl sink for equipment washing and a separate suitably sized sink for food preparation of stainless steel supplied with—
hot and cold water; and
in integral drainer on at least one side or a third bowl,
satisfies TAS I4P11.
(2) A sink installed adjacent to a wall or other vertical surface, that is fitted with an integral flashing to that wall or vertical surface to a height of not less than 150 mm, satisfies TAS I4P11.
(3) A sink provided with an integral surround not less than 150 mm wide except on sides with an integral flashing as in (2), satisfies TAS I4P11.
(4) A cleaner’s sink separated from food storage and handling areas provided for the emptying of cleaning water, satisfies TAS I4P11.