Tasmania variation · NCC 2025 Volume One

TAS I4P11 Fixtures, fittings and equipment

TAS Part I4 Food premises

Open on NCC Online ↗

Delete clause I4P11 and insert TAS I4P11 as follows:

Fixtures, fittings and equipment must—

be adequate for the production of wholesome food; and

be fit for their intended use; and

be designed, constructed, located and installed, and equipment must be located and, if necessary, installed, so that—

there is no likelihood that they will cause food contamination; and

they are able to be easily and effectively cleaned; and

adjacent floors, walls, ceilings and other surfaces are able to be easily and effectively cleaned; and

to the extent that is practicable, they do not provide harbourage for pests; and

have food contact surfaces—

able to be easily and effectively cleaned and, if necessary, sanitised if there is a likelihood that they will cause food contamination; and

unable to absorb grease, food particles and water if there is a likelihood that they will cause food contamination; and

made of a material that will not contaminate food.

Changed since NCC 2022. See NCC 2022 Volume One TAS I4P11, or show what changed.

Delete clause I4P11 and insert TAS I4P11 as follows: Fixtures, fittings and equipment must — be adequate for the … and made of a material that will not contaminate food.

Removed words are struck through; added words are highlighted. Comparison of the text only.