Western Australia variation · NCC 2025 Volume One
WA I4D7 Fixed seating
WA Part I4 Public buildings
Delete clause I4D7 and insert WA I4D7 as follows:
Where fixed seating in a Class 9b WA public building is arranged in more than one row—
aisles must be provided on both sides of every row that contains more than 10 seats; and
the number of seats in a row must not exceed 42.
Changed since NCC 2022. See NCC 2022 Volume One WA I4D7, or show what changed.
Delete clause I4D7 and insert WA I4D7 as follows: Where fixed seating in a Class 9b WA public building … number of seats in a row must not exceed 42.
Removed words are struck through; added words are highlighted. Comparison of the text only.
Other states and territories
- NSW Delete clause I4D7 and insert NSW I4D7 as follows: A stage which is more than 50 m2 but not more than 150 m2 in area…
- SA Delete clause I4D7 and insert SA I4D7 as follows: E1D3 does not apply to a bulk grain storage facility.
- TAS Delete clause I4D7 and insert TAS I4D7 as follows: A mechanical ventilating exhaust system complying with the…