New South Wales variation · NCC 2025 Volume One
NSW I4D7 Conventional stages: small stages
NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres
Delete clause I4D7 and insert NSW I4D7 as follows:
A stage which is more than 50 m2 but not more than 150 m2 in area must have 2 or more means of egress from the stage and backstage area provided otherwise than through the proscenium wall.
Changed since NCC 2022. See NCC 2022 Volume One NSW I4D7, or show what changed.
Delete clause I4D7 and insert NSW I4D7 as follows: A stage which is more than 50 m2 but not … and backstage area provided otherwise than through the proscenium wall.
Removed words are struck through; added words are highlighted. Comparison of the text only.
Other states and territories
- WA Delete clause I4D7 and insert WA I4D7 as follows: Where fixed seating in a Class 9b WA public building is arranged in…
- SA Delete clause I4D7 and insert SA I4D7 as follows: E1D3 does not apply to a bulk grain storage facility.
- TAS Delete clause I4D7 and insert TAS I4D7 as follows: A mechanical ventilating exhaust system complying with the…