10.2.2 Shower area (enclosed and unenclosed)
Part 10.2 Wet area waterproofing · NCC 2019: Table 3.8.1.1
(1) For a shower area with a hob, step-down or level threshold, the following applies:
The floor of the shower area must be waterproof, including any hob or step-down (see Figure 10.2.2); and
The walls of the shower area must be waterproof not less than 1800 mm above the floor substrate (see Figure 10.2.2).
Wall junctions and joints within the shower area must be waterproof not less than 40 mm either side of the junction (see Figure 10.2.2).
Wall/floor junctions within the shower area must be waterproof (see Figure 10.2.2).
Penetrations within the shower area must be waterproof.
(2) A shower with a preformed shower base must also comply with the requirements of (1), except for (a) which is not applicable.
Figure 10.2.2 Extent of treatment for shower areas — concrete compressed fibre-cement and fibre-cement sheet floors
Figure Notes
Wall/floor junction heights are to be as per 10.2.2 to 10.2.6 (as applicable).
Notes
Where a shower is above a bath or spa, use requirements for shower.
Changed in NCC 2025. See ABCB Housing Provisions 2025 10.2.2, or show what changed.
(1) For a shower area with a hob, step-down or … junctions and joints within the shower area must be waterproof not less than 40 mm either side of the junction (see Figure 10.2.2). Wall/floor junctions within the shower area must … is above a bath or spa, use requirements for shower.
Removed words are struck through; added words are highlighted. Comparison of the text only.