Housing Provisions clause · ABCB Housing Provisions 2022

10.2.23 Penetrations

Part 10.2 Wet area waterproofing

Open 10.2.23 on NCC Online ↗

Penetrations within shower areas must comply with the following:

Penetrations for taps, shower nozzles and the like must be waterproofed by sealing with—

sealants; or

proprietary flange systems; or

a combination of (i) and (ii).

The spindle housing of the tap body must be able to be removed to enable replacement of the washer without damaging the seal.

The following must be waterproofed:

All penetrations due to mechanical fixings or fastenings of substrate materials.

Any penetration of the surface materials due to mechanical fixings or fastenings.

Recessed soap holders (niches) and the like.

Tap and spout penetrations on horizontal surfaces surrounding baths and spas must be waterproofed by—

sealing the tap body to the substrate with sealants; or

proprietary flange systems.

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 10.2.23.