13.4.6 Construction of ceilings, walls and floors

Part 13.4 Building sealing · NCC 2019: 3.12.3.5

Open 13.4.6 on NCC Online ↗
Varied in NT. Check the variation for your state.

(1) Ceilings, walls, floors and any opening such as a window frame, door frame, roof light frame or the like must be constructed to minimise air leakage in accordance with (2) when forming part of the external fabric of—

a conditioned space; or

a habitable room in climate zones 4, 5, 6, 7 and 8.

(2) Construction required by (1) must be—

enclosed by internal lining systems that are close fitting at ceiling, wall and floor junctions; or

sealed at junctions and penetrations with—

close-fitting architrave, skirting or cornice; or

expanding foam, rubber compressive strip, caulking or the like.